Installation, cont’d
MLC 52 Series MediaLink Controller • Installation
2-12
Wiring for IR remote control
An optional IR Link or IRL 20 can be connected to the IR In pole of the control
connector to enable the MLC to receive IR signals from the IR 452.
Only one IR Link
or
one IRL 20 can be attached to the MLC 52.
To wire the IR Link for use with your MLC, follow these steps:
1
.
Prepare the site where the IR Link will be installed and install a wall box,
following the directions in the
IR Link User’s Manual
, provided with your
IR Link equipment.
2
.
Cut the required length of Extron CTL (Comm-Link) cable to go between the
MLC 52 and the IR Link. The power cable length should not exceed 150'
(45.7 m).
3
.
Attach a 3.5 mm, 5-pole captive screw connector to one end of the cable and a
6-pole captive screw connector to the other end. Only three wires are
required:
•
A
(MLC) to
A
(IR Link)
•
B
(MLC) to
B
(IR Link)
•
C
(MLC) to
D
(IR Link)
Connect the wires as shown in the illustration below. Connectors are
included with the IR Link, but the cable must be purchased separately.
4
.
Plug the 5-pole connector into one of the IR Link’s communications
connectors.
5
.
Plug the 6-pole connector into the rear panel control port of the MLC 52.
Wiring and using the IR Link for IR remote control
Connect only one IR Link. Do not connect more than one IR Link, either in
parallel or in series.
IR Link
F E D C B A
A B C D E
D
B
A
Modulated IR
+12VDC
Ground ( )
MLC 52
Control
Port
IR in
C
B
A
Total distance
from MLC is
150' (45.7 m) max.
SIGNAL
IR LINK
IR Link
IR Signal
Repeater
SIGNAL
IR LINK
MLC 52 or MLC 52 VC
MLC 52
DISPLAY
ON
PC
VIDEO
OFF
VOL
VOL
30'
(12 m)
IR 452 Remote
Control
SY
STEM REMO
TE
FR
ONT P
A
NEL
DV
D
VCR
DV
D
VCR
TV/VCR
VO
L
VO
L
PC
VIDEO
CHANNEL
IR 452
im Vertrieb von
CAMBOARD Electronics
www.camboard.de
Tel. 07131 911201