Kongsberg C-series
Fuse location
1 – Y-motor with encoder.
2 – TCU.
3 – AC amplifier for Y.
4 – P2 (Z2) – motor
5 - Status lamp
6 – P1 (Z1) – motor.
Procedure
1.
Remove Y cover.
2.
Remove cover from AC amplifier unit.
3.
Check fuses F2 – F5 with ohm - meter. If blown, replace with a new identical fuse.
4.
Replace covers.
5.
Insert main power cable into the wall socket and turn main power ON.
Fuse details
T 10A 250V (5 X 20 mm).
165