19
Kongsberg C-series
Calibrate Horizontal #2 Position
Reset to Factory Default Settings
Pressing the red Reset to Default Settings button will reset all parameters to factory settings.
19.9. Stacker Sequence of Operation
9.1 Homing the Stacker
The Stacker must be homed when power is first applied to the machine.
During the homing cycle first the carriage beam moves to its home position which is the located in the
full upward beam position.
Then the gantry moves to its home position which is located in the far reverse position where the
gantry is in the position to lower to the stacking pallet.
Homing is initiated by placing the Mode selector switch to Auto and then pressing the Home Stacker
button on the touch screen Stacker Main screen.
9.2 Stacker Find Stack
Once the machine is Homed, or whenever a new pallet is placed into the stacker, it is advantageous to
allow the stacker to determine the height of the stack.
Pressing the Find Stack button on the Stacker Main screen will cause the carriage beam to begin
lowering in search of the top of the stack.
When the plunger sensor detects the top of the stack, the stack height is recorded, and the carriage
beam returns to Home position over the pallet.
9.3 Stacker Sequence of Operation
1.
Pick Cut Board from the Cutter Command
The cutter signals the stacker to move to pick up the cut board when the cutter conveyor has
advanced the board to the unload position on a C64, and when the cutter beam has moved out of
the stacking collision zone.
2.
The gantry will move from the Park Position to the Pick Position over the cutting table.
3.
The Carriage Beam moves quickly down to a position just above the cut board.
246
Содержание Kongsberg C series
Страница 1: ...Kongsberg C series User Manual 05 2018 C series ...
Страница 8: ...Kongsberg C series 22 1 Machine 266 22 2 Tools 266 22 3 iPC 267 viii ...
Страница 40: ...7 Kongsberg C series 40 ...
Страница 65: ...10 Kongsberg C series 10 17 Board Size Not implemented yet 65 ...
Страница 171: ...14 Kongsberg C series Fuse F2 T2 5 A 250V 5x20mm 44347540 The same fuse size is used regardless 115V 230V 171 ...
Страница 214: ...18 Kongsberg C series Ensure the faulty situation is removed Press Safety Reset on Board Feeder to continue 214 ...
Страница 264: ...20 Kongsberg C series 5 Lift and turn the container to release it from the fixture 6 Empty the container 264 ...