19
Kongsberg C-series
The suction cup compensator’s carry the suction cups and have approximately 100mm of
vertical travel. The compensators allow all of the suction cups to come in contact with the
surface of the top board even on warped boards or uneven stacks of boards.
5.1.5 Feeder Plunger Sensor
The plunger sensor is a proximity switch that detects a target disk on the moving compensator.
The target disk moves up when the suction cup contacts the top board on the stack. This is the
method used to determine the height of the stack of boards and the top surface of the support
table.
5.1.6 Feeder Support Table
The ABF picks the top board off of the stack and transfers the board onto the support table.
The board is positioned so that the leading edge of the board is approximately 150mm onto
the cutter conveyor.
5.1.7 Feeder Support Table Roller
A roller is mounted on the support table at the board stack side of the table. The roller helps to
guide and transfer flexible materials onto the support table.
The roller is also used when the Esko roll unit is in service. The roll material rolls over the
support table roller, over the support table, and onto the cutter conveyor.
5.1.8 Feeder Electrical Enclosure
The electrical enclosure houses all of the electrical power and control devices. The Main Power
disconnect and Power On/Off push buttons are located on the door of the electrical enclosure.
The door of the enclosure is mechanically held closed by the main disconnect when the
disconnect is in the ON position.
DANGER: Never switch the disconnect ON with the electrical enclosure door open. Failure to
follow this warning may result in severe injury or death.
5.1.9 Controls Console and Pedestal
The control console contains the operator touch screen and the pushbuttons and selector
switches required to operate both the feeder and the stacker.
5.1.10 Feeder Utility Connections
The feeder main power cord, the compressed air connection, the Ethernet communications
cable, and the safety interconnect cable between the feeder/stacker and cutter, all connect to
the left side of the feeder electrical enclosure.
19.4.2. Stacker Machine Components
225
Содержание Kongsberg C series
Страница 1: ...Kongsberg C series User Manual 05 2018 C series ...
Страница 8: ...Kongsberg C series 22 1 Machine 266 22 2 Tools 266 22 3 iPC 267 viii ...
Страница 40: ...7 Kongsberg C series 40 ...
Страница 65: ...10 Kongsberg C series 10 17 Board Size Not implemented yet 65 ...
Страница 171: ...14 Kongsberg C series Fuse F2 T2 5 A 250V 5x20mm 44347540 The same fuse size is used regardless 115V 230V 171 ...
Страница 214: ...18 Kongsberg C series Ensure the faulty situation is removed Press Safety Reset on Board Feeder to continue 214 ...
Страница 264: ...20 Kongsberg C series 5 Lift and turn the container to release it from the fixture 6 Empty the container 264 ...