18
Kongsberg C-series
The plunger sensor has a maximum detection range of 1.5mm. Set the face of the sensor to a
distance of ½ mm away from the target washer.
12 - Feeder Fail to Pick Sheet Fault
When a board is picked, the suction cups
contact the board and then the board is slowly
raised to the “Pick Pause” position.
The vacuum level is checked when the board
arrives at the pick pause position.
If the vacuum level is lower than the Vacuum Level Set Point, a Fail to Pick Board Fault will
occur indicating that the board failed to be picked from the stack.
See section 8.4.3 for more information.
13 - Feeder Dropped Board Fault
The vacuum level is monitored while the board is raising from the Pick Pause position and
while the gantry is moving the board forward to the cutter conveyor.
A Dropped Board Fault will occur when the vacuum level falls below the Vacuum Level Set
Point which may indicate that the board has fallen off of the suction cups.
14 - Feeder Gantry Not In Pick Position Fault
The gantry must be located in the pick position over the pallet stack before the carriage will
move downward to pick a board.
A Gantry Not In Pick Position Fault will occur when the gantry is not in the pick position and a
pick command is issued by the cutter, or the Start pushbutton is pressed.
Remedy: Return the gantry to home position by pressing the Return Home button on the main
screen.
15 - Estop Not Energized Fault
This is an indication that no faults exist, but the emergency safety circuit still cannot be reset.
A possible cause is the Emergency Stop safety relay on the feeder has failed.
16 - Feeder or Stacker Servo Faulted
The conveyor belts are driven by a servo motor and servo drive controller.
The servo drive controller will detect whenever a fault condition exists with the servo system.
A servo fault will cause the emergency stop circuit to be de-energized.
The fault can be reset by addressing the cause of the servo fault and then pressing the blue
Fault Reset pushbutton.
The servo fault code will be displayed on the touch screen. Fault codes are also displayed on
the servo drive controller.
210
Содержание Kongsberg C series
Страница 1: ...Kongsberg C series User Manual 05 2018 C series ...
Страница 8: ...Kongsberg C series 22 1 Machine 266 22 2 Tools 266 22 3 iPC 267 viii ...
Страница 40: ...7 Kongsberg C series 40 ...
Страница 65: ...10 Kongsberg C series 10 17 Board Size Not implemented yet 65 ...
Страница 171: ...14 Kongsberg C series Fuse F2 T2 5 A 250V 5x20mm 44347540 The same fuse size is used regardless 115V 230V 171 ...
Страница 214: ...18 Kongsberg C series Ensure the faulty situation is removed Press Safety Reset on Board Feeder to continue 214 ...
Страница 264: ...20 Kongsberg C series 5 Lift and turn the container to release it from the fixture 6 Empty the container 264 ...