12
Kongsberg C-series
5
Regularly, perform a
Chuck
cleaning, following
the dedicated procedure;
Chuck Change and
Cleaning
on page 110.
Note:
Never use
Compressed Air
for
cleaning.
If a Milling Bit is stuck
If a
Milling Bit
is stuck in the
chuck
, the probable cause is low
air pressure
.
To release a
Milling Bit
from the
chuck
, a pressure of 7 bar is required.
If necessary, check the
Pressurized Air Regulator Valve
, or the
Pressurized Air
source.
If the bit is still stuck, see the
Chuck change and cleaning
section about how to unscrew the
chuck.
12.8.9. Chuck Change and Cleaning
Clean the
taper
and the
chuck
regularly for proper operation and optimum life time; at least
once a week, but more often if necessary.
Follow the procedure strictly.
Normally, the
chuck
has a long lifetime.
Extended vibrations or impacts may hurt the
chuck
, and cause bad milling results.
Trying a new
chuck
is the easiest way to identify if the
chuck
is the problem.
Running with a bad
chuck
will also increase the spindle wear.
Procedure
110
Содержание Kongsberg C series
Страница 1: ...Kongsberg C series User Manual 05 2018 C series ...
Страница 8: ...Kongsberg C series 22 1 Machine 266 22 2 Tools 266 22 3 iPC 267 viii ...
Страница 40: ...7 Kongsberg C series 40 ...
Страница 65: ...10 Kongsberg C series 10 17 Board Size Not implemented yet 65 ...
Страница 171: ...14 Kongsberg C series Fuse F2 T2 5 A 250V 5x20mm 44347540 The same fuse size is used regardless 115V 230V 171 ...
Страница 214: ...18 Kongsberg C series Ensure the faulty situation is removed Press Safety Reset on Board Feeder to continue 214 ...
Страница 264: ...20 Kongsberg C series 5 Lift and turn the container to release it from the fixture 6 Empty the container 264 ...