12.10.2. Startup
Ensure the following pre-requisites are in place for correct startup:
•
Note:
Never start the chiller without liquid.
• Signal cable (to inverter) is connected to the chiller unit.
• Chiller fluid level should be MAX. If not, fill with fresh water.
• If water temperature is too low, wait for the temperature to attain proper value ( 19
o
C /
66
o
F ).
The chiller is equipped with an internal, automatic heater.
First time startup
• Check that the supply matches the rated voltage.
• Check that the electrical connection has been made correctly.
12.10.3. Error Conditions
One common error signal is routed from the
Chiller
system to
the inverter and further into the control system.
The following error conditions are monitored:
• Temperature out of range (high and low)
• Water level too low
• Liquid flow too low (less than 0.5 l/min). The signal is 1
minute delayed, to be able to fill water hoses at startup..
125
Содержание Kongsberg C series
Страница 1: ...Kongsberg C series User Manual 05 2018 C series ...
Страница 8: ...Kongsberg C series 22 1 Machine 266 22 2 Tools 266 22 3 iPC 267 viii ...
Страница 40: ...7 Kongsberg C series 40 ...
Страница 65: ...10 Kongsberg C series 10 17 Board Size Not implemented yet 65 ...
Страница 171: ...14 Kongsberg C series Fuse F2 T2 5 A 250V 5x20mm 44347540 The same fuse size is used regardless 115V 230V 171 ...
Страница 214: ...18 Kongsberg C series Ensure the faulty situation is removed Press Safety Reset on Board Feeder to continue 214 ...
Страница 264: ...20 Kongsberg C series 5 Lift and turn the container to release it from the fixture 6 Empty the container 264 ...