19
Kongsberg C-series
Pressing the Front Vacuum Zone button will cause the Vacuum Generator valve, and the Front
Vacuum valve to be turned ON.
Vacuum will be supplied to the front vacuum zone which is the carriage beam front vacuum
cups.
Back Vacuum Zone
Pressing the Back Vacuum Zone button will cause the Vacuum Generator valve, and the Back
Vacuum valve to be turned ON.
Vacuum will be supplied to the back vacuum zone which is the carriage beam back vacuum
cups.
Front Release Air
Air is injected into the carriage beam to neutralize the beam vacuum when the board is
released to the support table.
Pressing the Front Release Air button will cause compressed air to be applied to the front
suction cups.
Back Release Air
Air is injected into the carriage beam to neutralize the beam vacuum when the board is
released to the support table.
Pressing the Back Release Air button will cause compressed air to be applied to the back
suction cups.
Vacuum Generator Air
The vacuum generator air valve is turned ON to supply compressed air to the vacuum
generator.
The vacuum generator uses compressed air to generate vacuum.
Pressing the Vacuum Generator Air button, will cause air to be supplied to the vacuum
generator.
Note: No vacuum will be applied to either the front or back vacuum zones.
Place Position Location
The Gantry transfers the board forward to the
support table and stops at the Place Position
Location.
The Place Position sets where the gantry will
place the board which in turn determines the
position leading edge of the board on the
cutter conveyor.
241
Содержание Kongsberg C series
Страница 1: ...Kongsberg C series User Manual 05 2018 C series ...
Страница 8: ...Kongsberg C series 22 1 Machine 266 22 2 Tools 266 22 3 iPC 267 viii ...
Страница 40: ...7 Kongsberg C series 40 ...
Страница 65: ...10 Kongsberg C series 10 17 Board Size Not implemented yet 65 ...
Страница 171: ...14 Kongsberg C series Fuse F2 T2 5 A 250V 5x20mm 44347540 The same fuse size is used regardless 115V 230V 171 ...
Страница 214: ...18 Kongsberg C series Ensure the faulty situation is removed Press Safety Reset on Board Feeder to continue 214 ...
Страница 264: ...20 Kongsberg C series 5 Lift and turn the container to release it from the fixture 6 Empty the container 264 ...