18
Kongsberg C-series
3 - Home Machine button
The Home Machine button is only enabled in Auto Mode.
The machine must be Homed each time power is turned ON to the machine.
Homing the machine causes the carriage beam and gantry to move to the Home positions. The
machine will not function in Auto mode until the machine is Homed. The rectangular bar in the
Home box will be Green once the machine has been homed.
4 - Cancel Vacuum button
The carriage beam vacuum is turned ON when a board is being picked and transferred to the
support table. To avoid dropping a board, the vacuum will remain ON when a machine fault
occurs during the transfer sequence.
Pressing the Cancel Vacuum button will cause the beam vacuum to be turned OFF.
5 - Return to Home Position button:
In Auto Mode, pressing the Return to Home Position button will cause the carriage beam
and gantry to return to Home position. This feature is helpful when recovering from a faulted
condition, or quickly returning the gantry to Home position after loading a new pallet of
boards, or after jogging the machine.
6 - Move to Place button
In Auto Mode, the Move to Place button will cause the Gantry to move to the forward most
position toward the cutter.
This feature is used to move the gantry forward out of the pick area when a new pallet of
boards is loaded into the i-BF.
Use the Return to Home Position button to move the gantry back to the Home position once
the pallet is positioned in the i-BF.
7 - Carriage Vacuum Level Display
The carriage vacuum level is displayed on the Main screen.
The vacuum level is expressed in mmHg.
Monitoring the vacuum level during board picking can be helpful in troubleshooting the i-BF for
proper board picking.
For example, low vacuum during picking may be a sign that not all of the suction cups made
contact with the top board before the carriage began raising the board.
8 - Servo Fault Codes
205
Содержание Kongsberg C series
Страница 1: ...Kongsberg C series User Manual 05 2018 C series ...
Страница 8: ...Kongsberg C series 22 1 Machine 266 22 2 Tools 266 22 3 iPC 267 viii ...
Страница 40: ...7 Kongsberg C series 40 ...
Страница 65: ...10 Kongsberg C series 10 17 Board Size Not implemented yet 65 ...
Страница 171: ...14 Kongsberg C series Fuse F2 T2 5 A 250V 5x20mm 44347540 The same fuse size is used regardless 115V 230V 171 ...
Страница 214: ...18 Kongsberg C series Ensure the faulty situation is removed Press Safety Reset on Board Feeder to continue 214 ...
Страница 264: ...20 Kongsberg C series 5 Lift and turn the container to release it from the fixture 6 Empty the container 264 ...