18
Kongsberg C-series
Typical Servo Fault Codes
1 - F602 or n602: Safe Torque Off
The emergency stop circuit is de-energized. Remedy: reset the feeder emergency stop circuit.
This fault is not communicated to the printer as it occurs every time the emergency stop circuit
is de-energized. However the F602, or n602 fault code will be displayed on the servo drive
whenever the emergency stop circuit is de-energized.
2 - F130, 132, 134: Problem with the servo encoder feedback
Possible causes:
• Break in the motor feedback cable.
• The motor feedback cable is unplugged from the servo drive or at the servo motor.
• Possible defective cable or servo motor encoder.
3 - F234, 237: Controls enclosure temperature too high
4 - F301: Servo motor overheated
Check for increased motor load due to binding in the conveyor system.
5 - F502: Bus under voltage
Check that AC power is present to the drive.
Check to see if a circuit breaker is tripped to OFF.
18.13. Suction Cups for Board Feeder
211
Содержание Kongsberg C series
Страница 1: ...Kongsberg C series User Manual 05 2018 C series ...
Страница 8: ...Kongsberg C series 22 1 Machine 266 22 2 Tools 266 22 3 iPC 267 viii ...
Страница 40: ...7 Kongsberg C series 40 ...
Страница 65: ...10 Kongsberg C series 10 17 Board Size Not implemented yet 65 ...
Страница 171: ...14 Kongsberg C series Fuse F2 T2 5 A 250V 5x20mm 44347540 The same fuse size is used regardless 115V 230V 171 ...
Страница 214: ...18 Kongsberg C series Ensure the faulty situation is removed Press Safety Reset on Board Feeder to continue 214 ...
Страница 264: ...20 Kongsberg C series 5 Lift and turn the container to release it from the fixture 6 Empty the container 264 ...