Functions 4. REMOTE1
24
4. REMOTE1
Be sure to operate the system with a functional interlock switch on the safe-
guard. It is dangerous to operate the system with the switch wound in tape,
or without the on/off conditions since the safeguard input functions will not
operate.
REMOTE1 has input terminals for the safeguard and the emergency stop.
In order to maintain a safe working zone, it is necessary to erect a safety enclosure around
the manipulator. The interlock switch of this safeguard should be connected to RE-
MOTE1. Safety functions such as momentary interruption of the program and switch to
low power mode are activated when the safeguard is opened.
The REMOTE 1 is provided with a pin for an extended emergency stop circuit for the user
to connect their own emergency device unit. Again, wiring for the emergency stop circuit
in a system with multiple robots differs from the way how the circuit is connected in a sys-
tem with a single robot. Refer to a section, “Wiring examples of the extended emergency
stop circuit”, in later pages.
REMOTE
REMOTE board
WARNING
P TYPE