Functions 9. Switch Types and Jumper Pin Set Up
60
9.2 Software switches
SD1 to 3 are hardware switches. Switches that you set using software are called “software
switches.” Controller has six such software switches, SS1 to 6. You set them from a
personal computer. The functions of these software switches are shown below. See the
programming support software manual for details on setting software switches.
The setting of bits that are labeled “(Reserved for system)” cannot be changed.
Software switch settings are saved even when power is turned off, but they are initialized at
the system initialization by MPU board DIP switch SD1-1 and all assume the OFF state.
SS1
Bit No.
Function
ON OFF
1
Selection of the remote
REMOTE3 (I/O)
REMOTE2 (operat-
ing unit)
2
(Reserved for system)
-
(Always OFF)
3
(Reserved for system)
-
(Always OFF)
4
(Reserved for system)
-
(Always OFF)
5
Execution of ON/OFF
commands when safeguard
is open in AUTO mode
Disabled
Enabled
6
Processing of output port
during emergency stop
Save
Reset
7
OFF ON
OFF
ON
8
Message lan-
guage selection
OFF
Japanese
OFF
English
ON
German
ON
-
SS2
Bit No.
Function
ON OFF
1 to 8
(Reserved for system)
SS3
Bit No.
Function
ON OFF
1 to 8
(Reserved for system)
SS4
Bit No.
Function
ON OFF
1 to 8
(Reserved for system)
Содержание SRC-320 ABS
Страница 1: ...SRC 320 ROBOT CONTROLLER Rev 9 EM01OC897F External E STOP...
Страница 2: ...ROBOT CONTROLLER SRC 320 Rev 9...
Страница 3: ...i ROBOT CONTROLLER SRC 320 Rev 9 Copyright 1995 2001 SEIKO EPSON CORPORATION All rights reserved...
Страница 14: ...xii...
Страница 84: ...Functions 11 Specifications 70...
Страница 91: ...Maintenance 2 Outline of Structure 77 2 3 Diagram of cable connections ES EC BN BNA RT3300...
Страница 92: ...Maintenance 2 Outline of Structure 78 EL EH BL XM3000...
Страница 176: ...Maintenance 16 Maintenance Parts List 162...