Functions 4. REMOTE1
31
*1 These are “normally closed” contacts which open upon the occurrence of a system error.
By using the jumper pins on the REMOTE board, it is possible to output other condi-
tions.
Jumper pin
Function when shorted
XP2
outputs for emergency stop occurrence
XP3
also outputs for error occurrence
There is a possibility that there will be no output if the internal cont24V power
is abnormal.
*2 To the dynamic brake relay control input pin, you may connect the in24V
power from the controller only. Connecting other power sources, such as 24V power
for the user cable or 24V outside power source, should be avoided.
*3 There are two safeguard inputs provided for REMOTE1. When the status of two in-
puts is different, CPU will take the safeguard input circuit as malfunction, and will is-
sue an error. Therefore, it’s recommendable to use a two-contacts switch.
If it’s not avoidable to use a one-contact switch, be sure to short the jumper pin XP6 on
the REMOTE board, so that the other input to which a switch is not connected will be
connected internally.
1
13
26
14
2
12
26
15
1
13
25
14
REMOTE1 connector
Controller side
REMOTE1 connector
Cable side
(details for wiring)
Содержание SRC-320 ABS
Страница 1: ...SRC 320 ROBOT CONTROLLER Rev 9 EM01OC897F External E STOP...
Страница 2: ...ROBOT CONTROLLER SRC 320 Rev 9...
Страница 3: ...i ROBOT CONTROLLER SRC 320 Rev 9 Copyright 1995 2001 SEIKO EPSON CORPORATION All rights reserved...
Страница 14: ...xii...
Страница 84: ...Functions 11 Specifications 70...
Страница 91: ...Maintenance 2 Outline of Structure 77 2 3 Diagram of cable connections ES EC BN BNA RT3300...
Страница 92: ...Maintenance 2 Outline of Structure 78 EL EH BL XM3000...
Страница 176: ...Maintenance 16 Maintenance Parts List 162...