Functions 1. Part Names and Functions
5
1.2 Rear panel
⑬
⑭
⑪
⑩
⑨
④
⑥
⑫
⑦
⑧
②
③
⑤
①
EXT
ER
N
A
L E.ST
O
P
①
POWER cable
Cable for controller AC power.
It is composed of two power leads (brown, blue) and an earth lead (green/yellow).
②
PSU board
Circuit board for controller, manipulator, and peripheral units’ power.
③
REMOTE board
Interface board having four connectors for REMOTE1&2 and RS-232C #20/#21.
④
REMOTE1
Connector for safeguard and emergency stop inputs. The safeguard input has safety fea-
tures such as temporary program stop and low power mode.
The emergency stop input achieves robot emergency stop. This input terminal is “nor-
mally closed” so that if no cable is connected, the robot is in the emergency stop condition
and will not operate.
Connect a “normally closed” emergency stop switch with the cable connector that came as
a standard accessory.
⑤
REMOTE2
Connector specifically for the operating unit (option: OPU-300 or OPU-320). It can be
used in the AUTO mode.
If there is no cable connected, the robot is in the emergency stop condition. If you do not
use the operating unit, connect a “normally closed” emergency stop switch with the cable
connector that came as a standard accessory. Further, it will be necessary to make a mode
switching circuit or similar modification.
⑥
RS-232C #20, #21
Connector for the RS-232C serial interface. It is used for communication between robots,
peripheral units, or host computers.
Содержание SRC-320 ABS
Страница 1: ...SRC 320 ROBOT CONTROLLER Rev 9 EM01OC897F External E STOP...
Страница 2: ...ROBOT CONTROLLER SRC 320 Rev 9...
Страница 3: ...i ROBOT CONTROLLER SRC 320 Rev 9 Copyright 1995 2001 SEIKO EPSON CORPORATION All rights reserved...
Страница 14: ...xii...
Страница 84: ...Functions 11 Specifications 70...
Страница 91: ...Maintenance 2 Outline of Structure 77 2 3 Diagram of cable connections ES EC BN BNA RT3300...
Страница 92: ...Maintenance 2 Outline of Structure 78 EL EH BL XM3000...
Страница 176: ...Maintenance 16 Maintenance Parts List 162...