Maintenance 8. REMOTE Board
117
8. REMOTE Board
8.1 Layout and function of REMOTE board parts
The REMOTE board controls 7-segment display of the front panel as well as REMOTE1,
REMOTE2 and RS-232C #20 and #21.
①
Jumper pins (XP2 to 8)
The functions of the jumper pins are described in the table below. Do not change the
setting of XP1.
Pin No.
Function when shorted
Setting
XP2
Also outputs for emergency stop occurrence
Open
XP3
Also outputs for error occurrence
Open
XP4
XP5
1 - 2 : Latches the state of “safeguard open”
2 - 3 : Does not latch the state of “safeguard open”
Jump 1 and 2
XP6
Uses one-contact safeguard switch
Open
XP7
1 - 2 : Outputs the safeguard status that CPU recognized
2 - 3 : Outputs the actual safeguard status
Jump 1 and 2
XP8
(Reserved for system)
Open
XP9
Factory-set and fixed
Jump 1 and 2
②
RS-232C driver IC (U10 to 13)
IC No.
Name
Used for
U10 TEACH
interface
U11
RS-232C #21 interface
U12
RS-232C #20 interface
U13
MC145406P
REMOTE2 (OPU) interface
Handle
②
②
②
①
①
Содержание SRC-320 ABS
Страница 1: ...SRC 320 ROBOT CONTROLLER Rev 9 EM01OC897F External E STOP...
Страница 2: ...ROBOT CONTROLLER SRC 320 Rev 9...
Страница 3: ...i ROBOT CONTROLLER SRC 320 Rev 9 Copyright 1995 2001 SEIKO EPSON CORPORATION All rights reserved...
Страница 14: ...xii...
Страница 84: ...Functions 11 Specifications 70...
Страница 91: ...Maintenance 2 Outline of Structure 77 2 3 Diagram of cable connections ES EC BN BNA RT3300...
Страница 92: ...Maintenance 2 Outline of Structure 78 EL EH BL XM3000...
Страница 176: ...Maintenance 16 Maintenance Parts List 162...