Timing chart for safeguard input
Safeguard output turns ON 5ms after the input of Safeguard while at the START state.
After 320ms, PAUSE output turns ON and START output turns OFF.
The PAUSE state is maintained while the Safeguard input is ON (the “Safeguard open” is
latched).
Safeguard output turns OFF 5ms after the Safeguard input turns OFF (when the safety door
is closed). Close the safety door (to turn OFF the input of Safeguard) and turn ON the
Latch Release input to restart.
While PAUSE output is ON, RESET can be input.
Safeguard input
Safeguard output
START output
PAUSE output
5 ms
5 ms
320 ms