Functions 8. RS-232C
57
Wiring example
A common wiring example is shown below.
[Controller]
[Connected equipment connector]
Signal
Pin No.
Pin No.
Signal
SD 3
2 SD
RD 2
3 RD
SG 5
7 SG
RS 7
4 RS
CS 8
5 CS
- -
6
DR
CD 1
8 CD
ER 4
20 ER
Clamp hood
1
FG
The following example is for CS control.
Because the controller does not perform RS control, it cannot control transmissions from
the connected equipment.
[Controller]
[Connected equipment connector]
Signal
Pin No.
Pin No.
Signal
SD 3
2 SD
RD 2
3 RD
SG 5
7 SG
RS 7
4 RS
CS 8
5 CS
-
-
6
DR
CD 1
8 CD
ER 4
20 ER
Clamp hood
1
FG
* In this example, controller-side CS input uses RS output of the connected equipment.