Product description
Prothermo NMT532
10
Hauser
3
Product description
3.1
Product design
Prothermo NMT532 is a multi-spot Pt100 average thermometer combined with a local
HART signal converter to meet the demand of temperature measurement for inventory
control applications. NMT532 consists of Max. 6 temperature elements which have
different length with fixed (2m or 3m) interval. It is best suited connected to Proservo
NMS5, NMS8x, or Hauser Micropilot S-series radars and the Tank Side Monitor
NRF590. Mounted on the tank top, NMT532 provides temperature information on the two
wire, intrinsically safe (i.s.) powered local HART loop.
3.2
Technical data
Item
Details
Application
NMT532 performs precise liquid and gas phase average temperature measurement in bulk storage tank applications.
• Flange installation: Standard 50.8 mm (2 in)
• temperature measurement range: Overall18.5 m (60.70 ft)
Measuring principle Temperature measurement
• Up to 6 temperature elements spaced evenly over the length of the flexible tube
• Pt100, IEC 60751/DIN EN 60751 Class A temperature elements
Measured variable
Temperature conversion range: –200 to 100 °C (–328 to 212 °F)
Measuring range
–200 to 100 °C (–328 to 212 °F)
Output signal
Local HART protocol (multi drop local HART loop connection)
Alarm signal
Error information can be accessed via the following interfaces and transmitted digital protocol
• NRF590 (BA00256F, BA00257F)
• NMS5 (BA00401G)
• NMS8x (BA1456G, BA1459G, BA1462G)
• NMR8x (BA01450G, BA01453G)
• NRF81 (BA01465G)
Local HART load
Minimum loading for local HART circuit: 250 Ω
Cable entry
• Thread NPT1/2
• Thread M20
Supply voltage
DC 16 to 30 V: Ex ia
Power consumption 6 mA
Measured value
resolution
• Temperature: ≤ 0.1 °C (0.18 °F)
• WB: ≤ 0.1 mm (0.004 in)
Maximum
measurement error
The values below represent performances under the reference conditions (including linearity, repeatability, hysteresis).
Conversion accuracy
Temperature
Standard spec.
± 0.1 °C (0.18 °F)
Probe system
Temperature
Standard spec.
± 0.15 °C + 0.002 °C x |t| (0.27 °F + 0.0036 °F |t|)
IEC 60751 / DIN EN 60751 / JIS C1604 Class A temperature element
Overall accuracy
Temperature
Standard spec.
Conversion accuracy ± 0.1 °C (0.18 °F) + Environmental effect ± 0.05 °C (0.09 °F) +
Class A temperature element ± 0.15 °C + 0.002 °C x |t| (0.27 °F + 0.0036 °F x |t|)
Ambient
temperature
–40 to 85 (–40 to 185)
Storage temperature –40 to 85 (–40 to 185)
Climate class
DIN EN 60068-2-38 (test Z/AD)