Operation
Prothermo NMT532
58
Hauser
Code
Display
Details
Range
0 to 16
777
214
Screen used for distinguishing the device ID when the NMT532
connects to a HART communication loop.
NOTICE
Device ID and HART address:
When a device ID is changed, a communication error may occur due to
inappropriate device ID and HART address combination.
‣
Ensure that the device ID and HART address are correct.
VH91
Previous Error
(Previous error)
Item type
Read only
Displays the error history. The error messages are the same as those in
VH80.
VH92
Error Dis. Sel.
(Error display
selection)
Item type
Selection
Default
0
Selection
0: OFF
1: ON
Selects the display of VH88 "Short Error Value" and VH89 "Open Error
Value."
OFF: VH88 and VH89 error messages are not sent to the host gauge.
This function automatically excludes defective elements in average
temperature calculations.
ON: Error messages are sent to the host gauge. As a result, the error
codes of VH88 and VH89 will appear on the host gauge's default
screen, and sent to the upper receiver as well.
VH93
Custody Mode
(Custody mode)
Item type
Read only
Default
Configured at the factory according to
specifications.
The overwrite protection of hardware is located on the main CPU
board (CN3 connector).
VH94
Polling Address
(Polling address)
Item type
Read / Write
Default
2
Range
1 to 15
Polling address used in local HART communication.
VH95
Manufacture ID
(Manufacturer ID)
Item type
Read only
Default
17 (Hauser)
Screen showing the manufacturer ID.
VH96
Software Version
(Software version)
Item type
Read only
Screen showing the installed software version.
VH98
Below Bottom
Item type
Selection
Default
0
Selection
0: OFF
1: ON
Displays an error when the liquid level drops below the bottom-point
element. If "ON" is selected, error code 29 will be displayed in VH80 and
VH91.
VH99
Device Type Code
(Device code)
Item type
Read only
Screen displaying the device type.
190: Temperature measurement function
Содержание Prothermo NMT532