Prothermo NMT532
Product description
Hauser
13
3.3.2
NMT532 Ex ia and Micropilot FMR S-series combination
Typical application of NMT532 con temperature probe
Temperature and level measurement with data collection and calculations via NRF81
allows for optimal inventory control. Basic functionality of NMT532 is displayed and
configured on NRF81. Detailed NMT532 functionality and data access can be performed
by FieldCare. NMT532 receives radar level data from NRF81 and then calculates liquid and
gas phase average temperature. Calculated and standard data including temperature
element raw data and device status are transmitted to NRF81.
All gathered data in the field interface unit are sent to inventory management
software (Tankvision) or to NMS8x, NMS5x, NMS7, NMR8x, NRF8x or NRF590.
2
3
1
a
b
c
d
f
e
4
g
h
A0038587
2
NMT532 Ex ia and NRF590 Ex d [ia] combination
a
FMR power supply (DC/Ex i)
b
Local HART (Ex i) loop (data transmission)
c
Gas temperature
d
Level
e
Liquid level temperature
f
Water
g
Fieldbus protocol
h
Power supply
1
FMR540
2
NMT532
3
NRF81/NRF590
4
Tankvision