Adjustment and settings
Prothermo NMT532
38
Hauser
Code
Display
Details
GVH480
Diagnostic
Displays error code messages. Refer to the error code chart in
this manual.
GVH482
Element number
The number of elements installed on the temperature
measurement tube is entered.
GVH485
Type of interval
Sets measurement element intervals. If the element intervals are
equal, select GVH487 "Element interval" to set the interval, and
then select GVH486 "Bottom point" to set the height of the
lowest edge of the elements. If the element intervals are not
equal, manually set the intervals.
This parameter configuration is only used to change the
theoretical element position within NMT532's software for
average temperature calculation. The physical positions of
the elements will not change.
GVH486
Bottom point
Sets the height of the lowest element. This is only set when the
elements have equal intervals.
This parameter configuration is only used to change the
theoretical element position within NMT532's software for
average temperature calculation. The physical positions of
the elements will not change.
GVH487
Element interval
The element interval is entered if "Equal interval" was selected in
GVH485 "Type of interval."
This parameter configuration is only used to change the
theoretical element position within NMT532's software for
average temperature calculation. The physical positions of
the elements will not change.