Installation
Prothermo NMT532
22
Hauser
Top anchor attachment procedure
The flexible tube must be lowered carefully without overbending and scratching the
inner edge of the nozzle hole.
1. Insert the flexible tube into a gasket and lower the flexible tube from the nozzle at
the top of the tank.
2. Rotate NMT532 for cabling in the most convenient way.
3. Straighten the tensioning wire, temporarily fix the end of the wire to the top anchor
and lower the wire.
4. Put the tensioning wire into the wire hook at the bottom of the tank.
5. Secure the tensioning wire twice through the hole at the bottom hook
6. Tighten the tensioning wire.
7. Wind the provided wire around the tensioning wire to secure the tensioning wire.
1
2
3
4
5
A0038598
14
Top anchor attachment 1
1
Provided wire
2
Temperature probe
3
Bottom hook
4
Wire hook
5
Tensioning wire
8. Use bolts to secure the flange of NMT532 to the installation nozzle on the top of the
tank.
Compress the anchor spring until it is 35 to 37 mm (1.38 to 1.46 in).
9. Secure the tension wire to the top anchor while drawing it by holding it down with a
foot or a hand.
10. Wrap the end of the tension wire once around the top anchor's axis, and tighten it
using two nuts.
11. Cut the excess tension wire.