Installation
Prothermo NMT532
28
Hauser
5.5.6
Thermo well method
The flexible tube is inserted into a thermo well in the fixed pipe.
Ø26 (1.02)
1
2
3
4
5
b
6
a
7
c
8
500
(19.69)
A0038603
20
Thermo well method. Unit of measurement mm (in)
a
Stilling pipe, ⌀ 50.8 mm (2 in) or more, depending on specifications
b
400 mm (15.57 in), Clearance of bottom hook
c
500 to 1
000 mm (19.69 to 39.37 in)
1
Electrical compartment
2
Cable entry as specified
3
Flange
4
Temperature probe
5
Fixed pipe
6
Gas hole
7
Gauge plate
8
Temperature element position #1 (bottom temperature element)
The installation procedure is the same as in the mounting on fixed roof tanks using
the top anchor.
Содержание Prothermo NMT532
Страница 72: ...www addresses endress com...