Operation
Prothermo NMT532
60
Hauser
1
A0038558
39
Screen 2
1
VH number
8.5
Temperature element near the tank bottom
This function is available in V1.53 and later versions. Temperature elements that are less
than 1 m (3.28 ft) from the tank bottom are handled as shown in the following table in
average liquid temperature calculations. Refer to the following figures for Case 1 and Case
2 in the following table.
Case
Application to average
temperature calculation for
temperature element
1
Elements that are at 1 m (3.28 ft) or higher
Not applicable
2
The level is 1 m (3.28 ft) or higher but elements are below
1 m (3.28 ft)
Applicable
3
The level is below 1 m (3.28 ft), and the elements below that are
below the level
Applicable
4
The temperature element is not in the liquid
Not applicable