Proline Promag 53 PROFIBUS DP/PA
Technical data
Hauser
169
Limiting flow
More detailed information in the “Nominal diameter and flow rate” section
Pressure loss
• No pressure loss if the sensor is installed in a pipe of the same nominal diameter (Promag H: only
DN 8 and larger).
• Pressure losses for configurations incorporating adapters according to DIN EN 545
10.1.10 Mechanical construction
Design / dimensions
The dimensions and lengths of the sensor and transmitter are contained in the separate
documentation “Technical information” for the respective measuring device, which you can
download in PDF format at www.endress.com. A list of the available “Technical information”
documents is contained in the “Supplementary documentation” section
Promag P
Nominal
diameter
Measuring tube
lining
Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] at various
fluid temperatures:
[mm]
[inch]
25 °C
80 °C
100 °C
130 °C
150 °C
180 °C
15
½"
PTFE
0
0
0
100
-
-
25
1"
PTFE / PFA
0/0
0/0
0/0
100/0
-/0
-/0
32
-
PTFE / PFA
0/0
0/0
0/0
100/0
-/0
-/0
40
1 ½"
PTFE / PFA
0/0
0/0
0/0
100/0
-/0
-/0
50
2"
PTFE / PFA
0/0
0/0
0/0
100/0
-/0
-/0
65
-
PTFE / PFA
0/0
*
40/0
130/0
-/0
-/0
80
3"
PTFE / PFA
0/0
*
40/0
130/0
-/0
-/0
100
4"
PTFE / PFA
0/0
*
135/0
170/0
-/0
-/0
125
-
PTFE / PFA
135/0
*
240/0
385/0
-/0
-/0
150
6"
PTFE / PFA
135/0
*
240/0
385/0
-/0
-/0
200
8"
PTFE / PFA
200/0
*
290/0
410/0
-/0
-/0
250
10"
PTFE
330
*
400
530
-
-
300
12"
PTFE
400
*
500
630
-
-
350
14"
PTFE
470
*
600
730
-
-
400
16"
PTFE
540
*
670
800
-
-
450
18"
PTFE
Partial vacuum is impermissible
500
20"
PTFE
600
24"
PTFE
* No value can be quoted.
Promag H Nominal
diameter
Measuring tube
lining
Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] at various
fluid temperatures:
[mm]
[inch]
25 °C
80 °C
100 °C
130 °C
150 °C
180 °C
2 to 100
1
/
12
to 4"
PFA
0
0
0
0
0
0