Technical data
Proline Promag 53 PROFIBUS DP/PA
168
Hauser
The permitted fluid temperature is dependent on the material of the seal:
• EPDM: –20 to +130 °C
• Silicone: –20 to +150 °C
• Viton: –20 to +150 °C
• Kalrez: –20 to +150 °C
Conductivity
Minimum conductivity
•
≥
5 µS/cm for liquids generally
•
≥
20 µS/cm for demineralized water
!
Note!
Note that, in the case of the remote version, the requisite minimum conductivity is also influenced
by the length of the connecting cable.
Fluid pressure range (nominal
pressure)
Promag W
• EN 1092-1 (DIN 2501):
PN 6 (DN 1200 to 2000), PN 10 (DN 200 to 2000), PN 16 (DN 65 to 2000), PN 25 (DN 200
to 1000), PN 40 (DN 25 to 150)
• ANSI B 16.5:
Class 150 (DN 1" to 24"), Class 300 (DN 1" to 6")
• AWWA:
Class D (DN 28" to 78")
• JIS B2238:
10 K (DN 50 to 300), 20 K (DN 25 to 300)
• AS 2129:
Table E (DN 80, 100, 150 to 400, 500, 600)
• AS 4087:
Cl. 14 (DN 80, 100, 150 to 400, 500, 600)
Promag P
• EN 1092-1 (DIN 2501):
PN 10 (DN 200 to 600), PN 16 (DN 65 to 600), PN 25 (DN 200 to 600), PN 40 (DN 15 to 150)
• ANSI B 16.5:
Class 150 (DN
1
/
2
" to 24"), Class 300 (DN
1
/
2
" to 6")
• JIS B2238:
10 K (DN 50 to 300), 20 K (DN 15 to 300)
• AS 2129:
Table E (DN 25, 50)
• AS 4087:
Cl. 14 (DN 50)
Promag H
The permissible nominal pressure depends on the process connection and the seal:
• 40 bar: flange, weld nipple (with O-ring seal)
• 16 bar: all other process connections
Resistance to partial vacuum
(measuring tube lining)
Promag W
Nominal diameter
Measuring tube
lining
Resistance of measuring tube lining to partial vacuum
Limit values for abs. pressure [mbar] at various
fluid temperatures
[mm]
[inch]
25 °C
50 °C
80° C
100 °C
130 °C
150 °C
180 °C
25 to 1000
1 to 40"
Polyurethane
0
0
-
-
-
-
-
65 to 2000
3 to 78"
Hard rubber
0
0
0
-
-
-
-