Proline Promag 53 PROFIBUS DP/PA
Troubleshooting
Hauser
155
a0004778
Fig. 72:
Wall-mount housing: removing and installing printed circuit boards
1
Housing cover
2
Electronics module
3
Ribbon cable (display module)
4
Screws of electronics compartment cover
5
Aperture for installing/removing boards
6
Power unit board
7
Amplifier board
7.1
Electrode signal cable (sensor)
7.2
Coil current cable (sensor)
7.3
S-DAT (sensor data storage device)
7.4
T-DAT (transmitter data storage device)
8
I/O board (flexible assignment)
8.1
F-CHIP (function chip for optional software)
8.2
Pluggable sub-modules (current, pulse/frequency and relay output)
3
4
1
2
3
6
7
8
5
5
7.1
7.3
7.4
7.2
8.1
5
INPUT/OUTPUT
4
INPUT/OUTPUT
3
1
2
3
4
W
E
N
O
1
2
3
4
W
E
N
O
1
2
3
4
W
E
N
O
1
2
3
4
W
E
N
O
8.2