Deltabar S FMD77, FMD78, PMD75 with FOUNDATION Fieldbus
Diagnostics and troubleshooting
Hauser
99
9.5
Overview of diagnostic events
9.5.1
Failure (F)
Diagnostic
Code
Error
response
Message/description XD_
ERROR
Value Bit
BLOCK_
ERROR
Value Bit
Cause
Measure
Prio-
rity
101 Alarm
F>Sensor
electronic
EEPROM error
20
0
– Electromagnetic effects are
greater than specifications in
the technical data.
(
See Section 10.) This
message normally only
appears briefly.
– Wait a few minutes.
– Restart the device. Perform
reset (Code 62).
– Block off electromagnetic
effects or eliminate source of
disturbance.
19
– Sensor defect.
– Replace sensor.
110
Alarm
F>Checksum error in
EEPROM:
configuration segment
23
0
– The supply voltage is
disconnected when writing.
– Reestablish supply voltage.
Perform reset if necessary
(code 7864) and recalibrate
the device.
6
– Electromagnetic effects are
greater than specifications in
the technical data.
(
See Section 10.)
– Block off electromagnetic
effects or eliminate sources of
disturbance.
– Main electronics defect.
– Replace main electronics.
113
Alarm
F>ROM failure in
transmitter electronic
20
0
– Main electronics defect.
– Replace main electronics.
1
121
Alarm
F>Checksum error in
factory segment of
EEPROM
23
0
– Main electronics defect.
– Replace main electronics.
5
122 Alarm
F>Sensor
not
connected
20
7
– Cable connection sensor –
main electronics
disconnected.
– Check cable connection and
repair if necessary.
14
– Electromagnetic effects are
greater than specifications in
the technical data.
(
See Section 10.)
– Block off electromagnetic
effects or eliminate source of
disturbance.
– Main electronics defect.
– Replace main electronics.
– Sensor defect.
– Replace sensor.
130
Alarm
F>EEPROM is defect.
23
0
– Main electronics defect.
– Replace main electronics.
11
131
Alarm
F>Checksum error in
EEPROM: min/max
segment
23
0
– Main electronics defect.
– Replace main electronics.
9
132
Alarm
F>Checksum error in
totalizer EEPROM
23
0
– Main electronics defect.
– Replace main electronics.
7
133
Alarm
F>Checksum error in
History EEPROM
23
0
– An error occurred when
writing.
– Perform reset (code 7864)
and recalibrate the device.
8
– Main electronics defect.
– Replace main electronics.
135
Alarm
F>Checksum error in
EEPROM FF segment
23
0
– Main electronics defect.
– Replace main electronics.
10
703
Alarm
F>Measurement error 20
0
– Fault in the main electronics. – Briefly disconnect device from
the power supply.
24
– Main electronics defect.
– Replace main electronics.
705
Alarm
F>Measurement error 20
0
– Fault in the main electronics. – Briefly disconnect device from
the power supply.
23
– Main electronics defect.
– Replace main electronics.