Pressure Transducer Block
Parameter name,
option "Symbolic name"
Parameter name,
option "Label"
Index Data type
Size
(Byte)
Storage
Class
Read
Writ
e
MODE_BLK
Reset codes
MEASURED_TEMPERATURE
Temperature
32
DS-65
5
D
x
MEASURED_TEMPERATURE_UNIT
Temp. eng. unit
33
Unsigned16
2
S
x
x
OOS
DEVICE_DIALOG
Device dialog
34
Unsigned8
1
D
x
SW_LOCK
Insert PIN no.
35
Unsigned16
2
S
x
x
AUTO, OOS,
MAN
7864, 333
STATUS_LOCKING
Status locking
36
Unsigned16
2
D
x
LINEARIZATION
Linearization
37
Unsigned8
2
S
x
x
OOS
7864, 333
SCALE_IN
Scale In
38
DS-68
11
S
x
x
OOS
7864, 333
SCALE_OUT
Scale Out
39
DS-68
11
S
x
x
OOS
7864, 333
DAMPING_VALUE
Damping value
40
Float
4
S
x
x
OOS
7864, 333
ZERO_POSITION_ADJUST
Pos. zero adjust
41
Unsigned8
1
D
x
x
OOS
POSITION_INPUT_VALUE
Pos. input value
42
Float
4
S
x
x
OOS
7864, 333,
2509
CALIBRATION_OFFSET
Calib. offset
43
Float
4
S
x
x
OOS
7864, 333,
2509
CUSTOMER_UNIT_PRESSURE
Customer unit P
44
Visible String 8
S
x
x
AUTO, OOS,
MAN
7864
CUSTOMER_FACTOR_UNIT_PRESS
Cust. unit. fact. P
45
Float
4
S
x
x
OOS
7864
LOW_TRIM_MEASURED
Lo trim measured
46
Float
4
S
x
2509
HIGH_TRIM_MEASURED
Hi trim measured
47
Float
4
S
x
2509
LEVEL_MODE
Level mode
48
Unsigned8
1
S
x
x
OOS
7864, 333
LINEAR_MEASURAND
Lin. measurand
49
Unsigned8
1
S
x
x
OOS
7864, 333
LINEARIZED_MEASURAND
Lin. measurand
50
Unsigned8
1
S
x
x
OOS
7864, 333
COMBINED_MEASURAND
Comb. measurand
51
Unsigned8
1
S
x
x
OOS
7864, 333
DENSITY_UNIT
Density unit
52
Unsigned16
2
S
x
x
OOS
7864, 333
HEIGHT_UNIT
Height unit
53
Unsigned16
2
S
x
x
OOS
7864, 333
CUSTOMER_HEIGHT_UNIT
Customer unit H
54
Visible String 8
S
x
x
AUTO, OOS,
MAN
7864
CUSTOMER_UNIT_FACTOR_HEIGHT
Cust. unit. fact. H
55
Float
4
S
x
x
OOS
7864
VOLUME_UNIT
Unit volume
56
Unsigned16
2
S
x
x
OOS
7864, 333
CUSTOMER_UNIT_VOLUME
Customer unit V
57
Visible String 8
S
x
x
AUTO, OOS,
MAN
7864
CUSTOMER_UNIT_FACTOR_VOLUME
Cust. unit. fact. V
58
Float
4
S
x
x
OOS
7864
MASS_UNIT
Unit mass
59
Unsigned16
2
S
x
x
OOS
7864, 333
CUSTOMER_UNIT_MASS
Customer unit M
60
Visible String 8
S
x
x
AUTO, OOS,
MAN
7864
CUSTOMER_UNIT_FACTOR_MASS
Cust. unit. fact. M
61
Float
8
S
x
x
OOS
7864
CALIBRATION_MODE
Calibration mode
62
Unsigned8
1
S
x
x
OOS
7864, 333
ADJUST_DENSITY
Adjust density
63
Float
4
S
x
x
OOS
7864, 333
ZERO_POSITION
Zero position
64
Float
4
S
x
x
OOS
7864, 333
EMPTY_CALIBRATION
Empty calib. level easy
65
Float
4
S
x
x
OOS
7864, 333
FULL_CALIBRATION
Full calib. level easy
66
Float
4
S
x
x
OOS
7864, 333
TANK_VOLUME
Tank volume
67
Float
4
S
x
x
OOS
7864, 333
TANK_HEIGHT
Tank height
68
Float
4
S
x
x
OOS
7864, 333
HUNDRED_PERCENT_VALUE
100% point
69
Float
4
S
x
x
OOS
7864, 333
LEVEL_MIN
Level Min.
70
Float
4
S
x
x
OOS
7864, 333
LEVEL_MAX
Level Max.
71
Float
4
S
x
x
OOS
7864, 333
PROCESS_DENSITY
Process density
72
Float
4
S
x
x
OOS
7864, 333
LINEARIZATION_TABLE_SELECTION
Table selection
73
Unsigned8
1
S
x
x
AUTO, OOS,
MAN
7864, 333
LINEARIZATION_EDIT_MODE
Edit table
74
Unsigned8
1
S
x
x
AUTO, OOS,
MAN
7864
LINEARIZATION_TABLE_PRE_EDIT
Editor table
75
Unsigned8
1
D
x
x
AUTO, OOS,
MAN
LINEARIZATION_TABLE_INDEX
Line numb:
76
Unsigned8
1
D
x
x
AUTO, OOS,
MAN
LINEARIZATION_TABLE_X_VALUE
X-value:
77
Float
4
S
x
x
AUTO, OOS,
MAN
7864
LINEARIZATION_TABLE_Y_VALUE
Y-value:
78
Float
4
S
x
x
AUTO, OOS,
MAN
7864
LINEARIZATION_TABLE_POST_EDIT
Table editor
79
Unsigned8
1
D
x
x
OOS
LINEARIZATION_TABLE_POST_VIEW
Measuring table
80
Unsigned8
1
D
x
x
AUTO, OOS,
MAN
LEVEL_TANK_DESCRIPTION
Tank description
81
Visible String 32
S
x
x
AUTO, OOS,
MAN
7864
SENSOR_PRESSURE
Sensor pressure
82
Float
4
D
x
PRESSURE
Pressure
83
Float
4
D
x
LEVEL_BEFORE_LINEARISATION
Level before lin
84
Float
4
D
x
Содержание Deltabar S FMD77
Страница 114: ...www addresses endress com 71336231 ...