Cerabar M, Deltapilot M
Commissioning
Hauser
51
Setting upper pressure value
4
Yes
No
5
The pressure present was saved as the upper pressure
value ("full pressure") and assigned to the upper level
value ("full calibration").
Applied pressure was not saved as the upper
pressure value. Observe the input limits.
8.4
Commissioning with an operating menu
Commissioning comprises the following steps:
• Function check → 48
• Selection of the language, measuring mode and pressure unit → 51
• Position adjustment/zero adjustment → 52
• Configuring measurement:
8.4.1
Selecting the language, measuring mode and pressure unit
Language (000)
Navigation
Main menu → Language
Write permission
Operators/Service engineers/Expert
Description
Select the menu language for the local display.
Options
• English
• Another language (as selected when ordering the device)
• Possibly a third language (language of the manufacturing plant)
Factory setting
English
Measuring mode (005)
Write permission
Operator/Maintenance/Expert
Description
Select the measuring mode.
The operating menu is structured differently depending on the measuring mode selected.
L
WARNING
Changing the measuring mode affects the span (URV)
This situation can result in product overflow.
‣
If the measuring mode is changed, the setting for the span (URV) must be checked in
the "Setup" operating menu and readjusted if necessary.
Selection
• Pressure
• Level
Factory setting
Pressure or according to order specifications