Operation
Cerabar M, Deltapilot M
42
Hauser
6.7
Resetting to factory settings (reset)
Reset via the local display
By entering a certain code, you can completely, or partially, reset the entries for the
parameters to the factory settings
. Enter the code by means of the "Enter reset code"
parameter (menu path: "Diagnosis" → "Reset" → "Enter reset code"). There are various reset
codes for the device. The following table illustrates which parameters are reset by the par-
ticular reset codes. Operation must be unlocked to reset parameters → 41.
Reset via IO-Link
• Reset to factory setting:
System → Device Management → System Command → Restore Factory Setting
• Reset to factory setting as per IO-Link (switch device off and on):
System → Device Management → System Command → Back-To-Box
• Device reset:
System → Device Management → System Command → Device Reset
Any customer-specific configuration carried out at the factory is not affected by a
reset (customer-specific configuration remains). If you want to change the customer-
specific configuration carried out at the factory, please contact Hauser Serv-
ice. As no separate service level is provided, the order code and serial number may be
changed without a specific unblocking code (e.g., after replacing the electronics).
Reset code
IO-Link command
Description and effect
62 (Device Reset)
296
PowerUp reset (warm start)
• The device is restarted
• Data are read back from the EEPROM again (processor is initialized again)
• Any simulation which may be running is ended
7864 (Restore to Factory Settings)
297
Total reset
• This code resets all the parameters apart from:
• Operating hours (162)
• Event logbook
• Lo Trim sensor (131)
• Hi Trim Sensor (132)
• Any simulation which may be running is ended
• The device is restarted
7864 (Back-To-Box)
131
Total reset (IO-Link)
• This code resets all the parameters apart from:
• Operating hours (162)
• Event logbook
• Lo Trim sensor (131)
• Hi Trim Sensor (132)
• Any simulation which may be running is ended
• Perform manual restart
1)
To be entered in "Diagnosis" → "Reset" → "Enter reset code" (124)
1)
The factory setting for the individual parameters is specified in the parameter description .