Run and operation explanation for inverter
13
4
Run and operation explanation for inverter
4.1 Run mode
EN600PV inverter have 3 kinds of run mode, following is in turn according to their priority,
jog run
→
solar mode
→
common run. Shown as Fig.4-1.
Fig.4-1 Run mode
0: Jog run
Upon receiving jog run command (for instance, press the key on keypad) during waiting
state, the inverter run at jog frequency (see function code F01.25~F01.29).
1: Photovoltaic operation
Set the PV operation control effective parameter F12.00>0, and the PV terminal prohibition
function of input terminal No. 72 is invalid, the inverter will enter the PV operation mode.
2: Common run
Common open loop run mode of general inverter.In above 6 kinds of run mode except “jog
run” the inverter can run according to kinds of frequency setting method.
4.2 Operation and use of key board
4.2.1 Keypad layout
The operating keyboard is the main unit of frequency inverter to accept commands,display
parameters. Keyboard outline diagram shown in Fig.4-2.