Function parameter schedule graph
48
F14.16 Forward speed limit
channel selection in
Torque control mode
0: Digital setting
1: AI1 Analog setting
2: AI2 Analog setting
3: Terminal UP/DOWN adjustment setting
4:Communication provision(Communication
address: 1D0A).
5: EAI1 Analog setting(expansion effective)
6: EAI2 Analog setting(expansion effective)
7: Rapid pulse setting(X8 terminal needs to choose
the corresponding function)
8: terminal pulse width setting(X8 terminal needs to
choose the corresponding function)
Note: This parameter is valid when F00.24=1.
1
0
×
F14.17 Reverse speed limit
channel selection in
Torque control mode
0: Digital setting
1: AI1 Analog setting
2: AI2 Analog setting
3: Terminal UP/DOWN adjustment setting
4: Communication provision(Communication
address: 1D0B).
5: EAI1 Analog setting (Expansion effective)
6: EAI2 Analog setting (Expansion effective)
7:Rapid pulse setting (X8 terminal needs to
choose the corresponding function)
8: Terminal pulse width setting (X8 terminal needs
to choose the corresponding function)
Note
:
This parameter is valid when F00.24=1.
1
0
×
F14.18 Forward speed limit
value in Torque
control mode
0.00Hz
~
upper limit frequency (This parameter
is valid when F00.24=1.)
0.01Hz 50.00Hz
○
F14.19 Reverse speed limit
value in Torque
control mode
0.00Hz
~
upper limit frequency (This parameter
is valid when F00.24=1.)
0.01Hz 50.00Hz
○
F14.20 Torque
Accelerate/Decelerate
time setting
0.000
~
60.000s (This parameter is valid when
F00.24=1.)
0.001s
0.100s
○
F14.21 Torque
compensation 0.0
~
100.0% (This parameter is valid when
F00.24=1.)
0.1%
0.0%
○
F14.22 Positive torque gain
regulation coefficient
50.0
~
150.0%(This parameter is valid when
F00.24=1.)
0.1%
100.0%
○
F14.23 Negative
torque
gain
regulation coefficient
50.0
~
150.0%(This parameter is valid when
F00.24=1.)
0.1%
100.0%
○
F14.24 Flux
braking
coefficient
0.0
~
300.0% (This parameter is valid when
F00.24=1.)
0.1%
0.0%
○
F14.25 Pre-excitation
start-up time constant
0.1
~
3.0 ( This parameter is valid when F00.24=1)
0.1 0.5 ×
F14.30 Torque
compensation
limit frequency
0.00Hz
~
upper limit frequency(This parameter
is valid when F00.24=1.)
0.01Hz
20.00
Hz
○
F15
-
Asynchronous Motor Parameter Group
Function
code
Name
Set range
Min.
unit
Factory
default
Modifi
-cation
F15.01 Asynchronous
motor
rated power
0.1
~
6553.5KW 0.1KW
Base
on
motor type
×
F15.02 Asynchronous
motor
rated voltage
1
~
690V
1V Base
on
motor type
×
F15.03 Asynchronous
motor
0.1
~
6553.5A
0.1A Base
on ×