Function parameter schedule graph
33
F06.11 Curve 2 Max. setting
Curve 2 inflexion setting
~
100.0% 0.1%
100.0%
○
F06.12 Corresponding
physical
quantity of curve 2 Max.
setting
0.0
~
100.0% 0.1%
100.0%
○
F06.13 Curve
3
min.
setting
0.0%
~
curve 3 inflexion 1 setting
0.1%
0.0%
○
F06.14 Corresponding physical
quantity of curve 3 min.
setting
0.0
~
100.0% 0.1%
0.0%
○
F06.15 Curve
3
inflexion
1
setting
Curve 3 min.setting~ curve 3 inflexion 2 setting 0.1%
30.0%
○
F06.16 Corresponding
physical
quantity of curve 3
inflexion 1 setting
0.0
~
100.0% 0.1%
30.0%
○
F06.17 Curve
3
inflexion
2
setting
Curve 3 inflexion 1setting~curve 3 Max.setting 0.1%
60.0%
○
F06.18 Corresponding
physical
quantity of curve 3
inflexion 2 setting
0.0
~
100.0% 0.1%
60.0%
○
F06.19 Curve 3 Max. setting
Curve 3 inflexion 1 setting
~
100.0% 0.1%
100.0%
○
F06.20 Corresponding
physical
quantity of curve 3 Max.
setting
0.0
~
100.0% 0.1%
100.0%
○
F06.21 Curve
lower
than
min.
input corresponding
selection
Units digit: curve 1 setting
0: Corresponds to min. setting corresponding
physical quantity.
1: 0.0% of the corresponding physical quantity.
Tens digit: curve 2 setting
Same as units digit.
Hundreds digit: curve 3 setting
Same as units digit.
Thousands digit: extended curve 1
Same as units digit.
Ten thousands digit: extended curve 2
Same as units digit.
1 11111
○
F07
-
Analog , Pulse input function parameter group
Function
code
Name
Set range
Min.
unit
Factory
default
Modifi
-cation
F07.00 AI1 input filter time
0.000
~
9.999s 0.001s
0.050s
×
F07.01 AI1 setting gain
0.000
~
9.999
0.001
1.006
○
F07.02 AI1 setting bias
0.0
~
100.0% 0.1%
0.5%
○
F07.03 AI2 input filter time
0.000
~
9.999s 0.001
0.050s
×
F07.04 AI2 setting gain
0.000
~
9.999
0.001
1.003
○
F07.05 AI2 setting bias
0.0
~
100.0% 0.1%
0.1%
○
F07.06 Analog setting bias polarity Units digit: AI1 setting bias polarity
0: Positive polarity.
1: Negative polarity.
Tens digit: AI2 setting bias polarity
0: Positive polarity.
1: Negative polarity.
1
01
○
F07.07 Pulse input filter time
0.000
~
9.999s 0.001
0.000s
×
F07.08 Pulse
input
gain
0.000
~
9.999
0.001
1.000
○
F07.09 Pulse
input
Max.
frequency 0.01
~
50.00KHz 0.01KHz 10.00KHz
○
F07.10 Pulse width input filter time 0.000
~
9.999s 0.001s
0.000s
×
F07.11 Pulse width input gain
0.000
~
9.999
0.001
1.000
○
ENC