Function parameter schedule graph
44
BIT3:Minimum power protection (A-45)
BIT4:Water full protection (A-46)
0:Free stop
1:Deceleration stop
F12.10 Photovoltaic time constant
1
~
100 1
10
○
F12.11 Sleep
voltage
0
~
600.0V 0.1V
200.0V
○
F12.13 Awakening
voltage
0
~
600.0V 0.1V
200.0V
○
F12.14 Awakening
time
0
~
6000.0s 0.1S
10.0S
○
F12.15 Low frequency protection
frequency
0
~
50.00hz 0.01Hz
10.00Hz
○
F12.16 Low frequency protection
detection time
0
~
6000.0s 0.1S
10.0S
○
F12.17 Low frequency protection
recovery time
0
~
6000.0s 0.1S
10.0S
○
F12.18 Minimum
power
protection
value
0
~
100.00kw 0.01KW
0.00KW
○
F12.19 Minimum
power
protection
time
0
~
6000.0s 0.1S
10.0S
○
F12.20 Minimum
power
protection
recovery time
0
~
6000.0s 0.1S
10.0S
○
F12.21 Overcurrent
protection
detection current
0.0A
~
199.9A 0.1A
0.0A
○
F12.22 Overcurrent
protection
detection time
0.0s
~
6000.0s 0.1s
10.0s
○
F12.23 Overcurrent
protection
automatic recovery time
0.0s
~
6000.0s 0.1s
10.0s
○
F12.24 Alarm recovery mode
Unit: Low Frequency Protection (A-42)
0: Automatic recovery
1: Manual recovery
Ten places: Dry pumping protection
(A-43)
0: Automatic recovery
1: Manual recovery
Set sequence switching
Hundreds: Overcurrent protection (A-44)
0: Automatic recovery
1: Manual recovery
Thousands: Minimum Power Protection
(A-45)
0: Automatic recovery
1: Manual recovery
1 0000
○
F12.25 Dry
pumping
protection
detection current
0.0A
~
199.9A 0.1A
0.0A
○
F12.26 Dry
pumping
protection
checkout time
0.0s
~
6000.0s 0.1s
10.0s
○
F12.27 Dry
pumping
protection
automatic recovery time
0.0s
~
6000.0s 0.1s
10.0s
○
F12.28 Water full protection
checkout time
0.0s
~
6000.0s 0.1s
10.0s
○
F12.29 Water full protection exit
time
0.0s
~
6000.0s 0.1s
10.0s
○
F12.30 DC current correction offset 0.0A
~
999.9A 0.1A
0.0A
○
F12.31 DC current correction ratio 0.0%
~
500.0% 0.1%
100.0%
○
F12.32 Power curve 0
0.0kw
~
999.9kw 0.1Kw
0.5kw
○
F12.33 Power curve 1
0.0kw
~
999.9kw 0.1Kw
1.0kw
○
F12.34 Power curve 2
0.0kw
~
999.9kw 0.1Kw
1.5kw
○
ENC