Debugging specification
61
The above parameter display when inverter stop by C-00~C-05 parameter group, pressing
to switch between these parameters. Pressing and then return to C-00 parameter monitor. For
example: pressing parameter switch from C-00 to C-01, continuous pressing the same button:
parameter switch from C-01 to C-02: then pressing return to C-00 parameter monitor.
Monitor contents various as different monitor parameter: refer to parameter F00.01.
6.1.2 On-off input function parameter group: F08
F08.18
Input terminal X1 function selection
Range:0
~
96
1
F08.19
Input terminal X2 function selection
Range:0
~
96
2
F08.20
Input terminal X3 function selection
Range:0
~
96
0
F08.21
Input terminal X4 function selection
Range:0
~
96
0
F08.22
Input terminal X5 function selection
Range:0
~
96
0
F08.23
Input terminal X6 function selection
Range:0
~
96
0
F08.24
Input terminal X7 function selection
Range:0
~
96
0
F08.25
Input terminal X8 function selection
Range:0
~
96
0
The function No. 70,71,72 of Multi-functional input terminal X1 ~ X8 can be selected
according to site needs.Detailed parameters and functions please see table 6-1
Table 6-1 Multi-functional input selection function table
Content
Function
Content
Related Function
70
Full-water inspection alarm
(
A-46
)
72
function prohibition on solar inverter
71
Reset of full water alarm
-
-
70:Full-water alarm(A-46)
. During the operation of the frequency converter, this function is
effective, and after maintaining F12.28 time, it enters the standby state of full water, and at the
same time, the keyboard warns "A-46".
71:Reset with full-water alarm.
When the pump is full-water standby, the terminal NO.70 is
invalid, and terminal No. 71 is effective and the holding time is longer than F12.29, the frequency
converter will automatically resume operation. If F12.28=0, terminal No. 70 and No. 71 will be
invalid.
72:Photovoltaic function prohibite.
When the terminal is effective, the photovoltaic
parameter group is invalid, and the inverters enter into debugging mode. Can only determine
whether the terminal function is effective when When the inverter is stopped. The changing the
terminal state is invalid during the inverter is running. The change of the terminal in operation will
not take effect until the next shutdown.
Note
Monitor parameter group C-00~C-05 have run and stop modes. For example C-00 display different
physical value under run and stop two modes.