Function parameter schedule graph
47
5: EAI1 Analog setting(Expansion effective)
6: EAI2 Analog setting(Expansion effective)
7: Rapid pulse setting ( X8 terminal needs to choose
the corresponding function)
8:Terminal pulse width setting (X8 terminal needs
to choose the corresponding function)
Tens digit: Electric torque limit channel selection
0: Digital setting (Determined by F14.09)
1: AI1 analog setting
2: AI2 analog setting
3: Terminal UP / DOWN adjustment setting
4: Reserved
5: EAI1 analog Setting (Extended Valid)
6: EAI2 analog setting (Extended Valid)
7: High-speed pulse setting
(X8 terminals need to select the appropriate
function)
8: Terminal pulse width setting
(X8 terminals need to select the appropriate
function)
Note: The maximum value of 1 ~ 8 channels
corresponds to F14.09
Hundreds digit: Braking torque limit channel
selection
0: Digital setting (Determined by F14.10)
1: AI1 analog setting
2: AI2 analog setting
3: Terminal UP/DOWN adjustment setting
4: Reserved
5: EAI1 analog Setting (Extended Valid)
6: EAI2 analog setting (Extended Valid)
7: High-speed pulse setting
(X8 terminals need to select the appropriate
function)
8: Terminal pulse width setting
(X8 terminals need to select the appropriate
function)
Note: The maximum value of 1 ~ 8 channels
corresponds to F14.10
F14.14 Torque
polarity
setting
0000
~
2112
Units digit: torque setting polarity
0: Positive
1: Negative
2: Defined by running command
Tens digit: Torque compensation polarity
0: The same as setting direction of torque
1: Opposite the setting direction of torque
Hundreds digit: F14.21 Compensation weakened
when the motor locked rotor
0: Invalid
1: Enable.
Thousands digit: Torque control anti-reverse
function
0: Invalid
1: Anti-reverse function is active continuously
2: Anti-reversal function enabled at startup.
1 2000
○
F14.15 Torque
digital
setting
value
0.0
~
200.0% (This parameter is valid when
F00.24=1 or 2)
0.1%
0.0%
○
ENC