Function parameter schedule graph
49
rated current
motor type
F15.04 Asynchronous
motor
rated frequency
0.00
~
600.00Hz 0.01Hz
Base
on
motor type
×
F15.05 Asynchronous
motor
rated rotational speed
0
~
60000r/min 1r/min
Base
on
motor type
×
F15.06 Asynchronous
motor
pole pairs No.
1
~
7
1 2 ×
F15.07 Asynchronous
motor
stator resistance
0.001
~
65.535
Ω
(Inverter power
<
7.5KW) 0.001
Ω
Base on
motor type
×
0.0001
~
6.5535
Ω
(Inverter power
≥
7.5KW)
0.0001
Ω
F15.08 Asynchronous
motor
rotor resistance
0.001
~
65.535
Ω
(Inverter power
<
7.5KW) 0.001
Ω
Base on
motor type
×
0.0001
~
6.5535
Ω
(Inverter power
≥
7.5KW)
0.0001
Ω
F15.09 Asynchronous
motor
leakage inductance
0.01
~
655.35mH (Inverter power
<
7.5KW) 0.01mH
Base
on
motor type
×
0.001
~
65.535mH (Inverter power
≥
7.5KW)
0.001mH
F15.10 Asynchronous
motor
mutual inductance
0.1
~
6553.5mH (Inverter power
<
7.5KW) 0.1mH
Base
on
motor type
×
0.01
~
655.35mH (Inverter power
≥
7.5KW) 0.01mH
F15.11 Asynchronous
motor
no load current
0.01
~
655.35A 0.01A
Base
on
motor type
×
F15.19 Motor
parameter
self-tuning selection
0: Inaction
1: Asynchronous motor stop to self-adjusting
2: Asynchronous motor rotate no-load to
self-adjusting
3: Reserved
Note
:
①
Before adjustment,The nameplate data
should be setting directly.
②
Motor parameter group can have special
default values, or can be modified by users,
or can be self-adjusted.
③
when parameter F15.01 is modified, the
other parameters of the motor will turn into
default values automatically.
1 0 ×
F18
-
Enhance Control Parameter Group
Function
code
Name
Set range
Min.
unit
Factory
default
Modifi
-cation
F18.00 Operation
panel
control frequency
binding
0: No binding
1: Operation keyboard digital setup
2:AI1 analog setup
3:AI2 analog setup
4: Terminal UP/DOWN adjusting setup
5: Communication provide (Modbus and external bus
use the same main frequency storage)
6:EAI1 analog setup(extension valid)
7:EAI2 analog setup(extension valid)
8:High speed pulse setup( X8 terminal need choose
the relative function)
9:Terminal pulse width setup(X8 terminal need choose
the relative function)
10:Terminal encoder provide(decide by X1,X2)
11
~
15: Reserved
1
0
○
F18.01 Terminal
control
frequency binding
Same as above
1
0
○
F18.02 Communication
control frequency
binding
Same as above
1
0
○