Function parameter schedule graph
43
F11.16 PID
regulation
lower
limit frequency
0.00Hz
~
upper limit frequency
0.01Hz 0.00Hz
○
F11.17 Integral
regulation
selection
0:When integral arrival separate PID threshold
value,stop integral adjusting
1:When integral arrival separate PID threshold
value,continue threshold value adjusting
1
0
○
F11.18 PID
threshold
of
the
integral separation
0.0
~
100.0% 0.1%
100.0%
○
F11.19 Preset
closed-loop
frequency
0.00Hz
~
upper limit frequency
0.01Hz 0.00Hz
○
F11.20 Holding
time
of
preset
closed-loop frequency
0.0
~
6000.0s 0.1s
0.0s
○
F11.21 Closed-loop
output
reversion selection
0:Close-loop output minus,low limit frequency
run.
1:Close-loop output minus,reverse run(effect by
run direction setting )
2:Determined by running demand
1
2
○
F11.22
Closed-loop output
Reversion frequency
upper limit
0.00Hz
~
upper limit frequency
0.01Hz 50.00Hz
○
F11.23 Multiple
closed-loop
provision 1
0.00
~
10.00V
0.01V
0.00V
○
F11.24 Multiple
closed-loop
provision 2
0.00
~
10.00V
0.01V
0.00V
○
F11.25 Multiple
closed-loop
provision 3
0.00
~
10.00V
0.01V
0.00V
○
F11.26 Multiple
closed-loop
provision 4
0.00
~
10.00V
0.01V
0.00V
○
F11.27 Multiple
closed-loop
provision 5
0.00
~
10.00V
0.01V
0.00V
○
F11.28 Multiple
closed-loop
provision 6
0.00
~
10.00V
0.01V
0.00V
○
F11.29 Multiple
closed-loop
provision 7
0.00
~
10.00V
0.01V
0.00V
○
F12
-
Solar Functional Parameter Table
Function
code
Name
Set range
Min.
unit
Factory
default
Modifi
-cation
F12.00 Solar water supply mode
selection
0: Invalid 1: MPPT Valid
2: CVT Valid
1 1 ×
F12.01 Upper limit voltage
80.0
~
100.0% 0.1%
90.0%
○
F12.02 Lower limit voltage
50.0
~
80.0% 0.1%
50.0%
○
F12.03 Search
interval
0
~
100.0s 0.1S
1.0S
○
F12.04 Voltage increase threshold
0.5
~
30.0% 0.1%
0.5%
○
F12.05 Proportional
gain
0.00
~
100.00 0.01
Based
on
motor type
○
F12.06 Integral
gain
0.01
~
10.00 0.01
Based
on
motor type
○
F12.07 Differential
gain
0.00
~
10.00 0.01
Based
on
motor type
○
F12.08 CVT
target
voltage
50.0
~
100.0% 0.1%
80.0%
○
F12.09 Protection stop mode
00
~
1F
BIT0:Low frequency protection (A-42)
BIT1:Dry pumping protection (A-43)
BIT2:Over current protection (A-44)
1 0000
○