Function parameter schedule graph
45
F12.35 Power curve 3
0.0kw
~
999.9kw 0.1Kw
2.0Kw
○
F12.36 Power curve 4
0.0kw
~
999.9kw 0.1Kw
2.5Kw
○
F12.37 Flow
curve
0
0.0m3/h
~
999.9m3/h 0.1m3/h
0.0m3/h
○
F12.38 Flow
curve
1
0.0m3/h
~
999.9m3/h 0.1m3/h
5.0m3/h
○
F12.39 Flow
curve
2
0.0m3/h
~
999.9m3/h 0.1m3/h
10.0m3/h
○
F12.40 Flow
curve
3
0.0m3/h
~
999.9m3/h 0.1m3/h
15.0m3/h
○
F12.41 Flow
curve
4
0.0m3/h
~
999.9m3/h 0.1m3/h
20.0m3/h
○
F12.42 Flow correction bias
0.0
~
999.9m3/h 0.1m3/h
0.0m3/h
○
F12.43 Flow correction gain
0.0%
~
999.9% 0.1%
100.0%
○
F12.44 Daily flow/day power is
cleared
0h
~
24h 1h
7h
○
F13
-
Traverse/ Fixed Length Control Function Parameter Group
Function
code
Name
Set range
Min.
unit
Factory
default
Modifi
-cation
F13.00 Traverse
function
selection
0: Traverse invalid
1: Traverse valid
1
0
×
F13.01 Traverse
operating
mode
Units digit: Enter mode
0: Automatically enter
1: Terminal enter manually
Tens digit:
0: Variable swing
1: Fixed swing
Hundreds digit: Traverse halt start mode selection
0: Restart
1: Start as previous halt record
Thousands digit: Traverse status reserve selection
0: No reserve
1: Reserve
1 0000
×
F13.02 Traverse
frequency
swing value
0.0
~
50.0% 0.1%
10.0%
○
F13.03 Sudden-Jump
frequency
0.0
~
50.0% 0.1%
2.0%
○
F13.04 Traverse
cycle
0.1
~
999.9s 0.1s
10.0s
○
F13.05 Triangular wave rising
time
0.0
~
98.0% (Traverse cycle)
0.1%
50.0%
○
F13.06 preset
frequency
of
Traverse
0.00
~
400.00Hz 0.01Hz 0.00Hz
○
F13.07 Traverse
preset
frequency waiting time
0.0
~
6000.0s 0.1s
0.0s
○
F13.08 Setting
length
0
~
65535(m\cm\mm)
1
0
○
F13.09 Number of pulses for
axis per circle
1
~
10000 1
1
○
F13.10 Axis
perimeter
0.01
~
655.35cm 0.01cm 10.00cm
○
F13.11 Percentage
of
remaining length
0.00%
~
100.00% 0.01%
0.00%
○
F13.12 Length
correction
coefficient
0.001
~
10.000 0.001
1.000
○
F13.13 After length arrival :
record length manage
Units digit: Reserved
Tens digit: Sets the unit of length
0: Meter(m)
1: Centimeter(cm)
2: Millimeter(mm)
Hundreds digit: Actions when the length is
reached
1 0000
○
ENC