Function parameter schedule graph
23
1: Keyboard button valid
F00.16 Multi-function
key
run command
channel switching
order selection
0: Keyboard control
→
terminal control
→
communication control
1: Keyboard control
←→
terminal control
2: Keyboard control
←→
communication control
3: Terminal control
←→
communication control
1
0
○
F00.17 Motor
speed
display coefficient
0.1
~
999.9% 0.1% 100.0%
○
F00.18 Line
velocity
display coefficient
0.1
~
999.9% 0.1%
1.0%
○
F00.19 Extended
Port
Parts
set
0: Invalid
1
~
3: Reserved
4: Analog input output extension card
5: Isolated type TX485 communication expansion card
6
~
10: Reserved
1
0
×
F00.20 Analog
input
terminal
configuration
Units digit:AI1 configuration
0: 0~10V input
1: 4~20mA input
Tens digit: AI2 configuration
0: -10~10V input
1: 4~20mA input
Hundreds digit: EAI1 configuration
0: 0~10V input
1: -10~10V input
2: 4~20mA input
Thousands digit: EAI2 configuration
0: 0~10V input
1: -10~10V input
2: 4~20mA input
1 1100
×
F00.21 Analog
output
terminal
configuration
Units digit: AO1 configuration
0: 0~10V output
1: 4~20mA output
Tens digit: AO2 configuration
0: 0~10V output
1: 4~20mA output
Hundreds digit: EAO1 configuration
0: 0~10V output
1: 4~20mA output
Thousands digit: EAO2 configuration
0: 0~10V output
1: 4~20mA output
2: 0~20mA output
1 0000
×
F00.22
Y output terminal
configuration
Units digit~ Hundreds digit: reserved
Thousands digit: Y4 output configuration
0: Open collector output
1: DO output
1
0000
×
F00.24
Motor control mode
0: V/F control(object to torque control)
1: No speed sensor vector control
2
、
3: Reserved
1
0
×
F00.25
Monitor parameter
2 selection
The same as parameter F00.01
1
4
○
F00.26
Busbar voltage
adjustment
coefficient
0.900
~
1.100
1
1.000
○
F00.27
Parameters copying
and Language
selection
Units digit: Reserved
Tens digit: parameter upload and download
0: Inaction
1
00
×