6 TECHNICAL AND ENVIRONMENTAL CHARACTERISTICS
6.1 ELECTRIC AND OPERATING CHARACTERISTICS
Power supply rate voltage (network):
100 ÷ 240V~ - -15/+10% - 50/60 Hz
Max absorption :
3A
AC/DC output rated voltage:
26V
⎓
Max AC/DC deliverable current:
4.85A
Placeable lead battery:
2x12V - 12Ah
KEY TO SYMBOLS
Symbol
Description
⎓
Direct input voltage
~
Alternating input voltage
See the installation manual of the device
6.2 WEATHER CHARACTERISTICS
Operating temperature range:
– 5 ÷ +40°C U.R. 95% @ 40°C
Storage temperature range:
-20 ÷ +70°C
6.3 AESTHETIC AND MECHANICAL CHARACTERISTICS
The control panel consists of a metal base and a plastic cover where the keypad is housed, together with the display
and the CPU.
The cover is hinged on the base short side.
The control boards, the Backplane, the AC/DC converter and the batteries are fitted on the metal base.
7 APPENDIXES
7.1 APPENDIX 1 – ERROR CODES FOR FAULT OF DEVICES
If a device undergoes a fault, this fault is detected by the control panel during the scanning phase and the user is
notified about it with a message:
FAULT ZXXX CYY PZZZ TT FWWW
NAME OF THE DEVICE
XXX
= number of the zone which the device belongs to
YY
= circuit which the device is connected to
ZZZ
= address of the device
TT
= type (in short) of the device
WWW
= fault code
If the device is an output module, the user is notified about the fault with one of the following messages, depending on
the fault:
FAULT EXT. CXX PYYY OM FZZZ
NAME OF THE MODULE
or:
FAULT CXX PYYY OM FZZZ
NAME OF THE MODULE
XX
= circuit which the module is connected to
YYY
= address of the module
ZZZ
= fault code