Model
P D T Spanning
Aantal
polen
Draaddoorsnede
(mm2)
Kabelbedekking
Kabellengte
(m)
Soort aansluitingen
F=Fase
N=Nul
T=Aarde
Max. vermogen bij:
opgerolde kabel (capaciteit 1
contact 16A op 230V)
uitgerolde kabel (belasting
verdeler 3 fasen)
280-230V-MF
280-230V-MF-P/S
●
- - Monofase 230 V 2
1
H05 VV-F (pvc)
17+1
F-N
900 W
1400 W
H07 RN-F (rubber)
12+1
F-N
900 W
1400 W
1,5
H05 VV-F (pvc)
15+1
F-N
1100 W
2300 W
2,5
H05 VV-F (pvc)
10+1
F-F-N-N
1900 W
3500 W
H07 RN-F (rubber)
8+1
F-F-N-N
1900 W
3500 W
●
- - Monofase 230 V 3
1
H05 VV-F (pvc)
14+1
F-N-T-T
900 W
1400 W
H07 RN-F (rubber)
10+1
F-N-T-T
900 W
1400 W
1,5
H05 VV-F (pvc)
14+1
F-N-T-T
1200 W
2300 W
H07 RN-F (rubber)
9+1
F-N-T-T
1200 W
2300 W
2,5
H05 VV-F (pvc)
9+1
F-F-N-N-T-T
1900 W
3500 W
H07 RN-F (rubber)
7+1
F-F-N-N-T-T
1900 W
3500 W
280-400V-TRF
●
- - Driefasen 400 V 4
1
H05 VV-F (pvc)
11+1
F-F-F-T-T
1100 W
2300 W
H07 RN-F (rubber)
10+1
F-F-F-T-T
1100 W
2300 W
1,5
H05 VV-F (pvc)
10+1
F-F-F-T-T
1400 W
4000 W
H07 RN-F (rubber)
8+1
F-F-F-T-T
1400 W
4000 W
2,5
H05 VV-F (pvc)
8+1
F-F-F-T-T
2000 W
6000 W
H07 RN-F (rubber)
5+1
F-F-F-T-T
2000 W
6000 W
●
- - Driefasen 400 V 5
1
H05 VV-F (pvc)
11+1
F-F-F-N-T-T
1000 W
2300 W
H07 RN-F (rubber)
10+1
F-F-F-N-T-T
1000 W
2300 W
1,5
H05 VV-F (pvc)
8+1
F-F-F-N-T-T
1400 W
4000 W
H07 RN-F (rubber)
7+1
F-F-F-N-T-T
1400 W
4000 W
280-MT
- - - -
-
6
pvc
15+1
T-T-T-T-T-T
Max. stroom afhankelijk van geïnstalleerde klem:
50 A (Mod. 280-MT-50A)
10 A (Mod. 280-MT-ADFL)
16
pvc
10+1
T-T-T-T-T-T
Max. stroom afhankelijk van geïnstalleerde klem:
100 A (Mod. 280-MT-100A)
290-230V
-
●
●
12 V ~
2
1
H05 VV-F (pvc)
15+1
F-N
Vermogen 50 VA (max. 4,5 A)
H07 RN-F (rubber)
14+1
F-N
-
●
●
24 V ~
2
1
H05 VV-F (pvc)
15+1
F-N
Vermogen 50 VA (max. 2,3 A)
H07 RN-F (rubber)
14+1
F-N
Gebruikstemperatuur
van -5°C tot + 40°C (van 23°F tot 104°F)
Beschermingsgraad
IP44 voor modellen zonder beschermhoes - IP45 voor modellen met beschermhoes
Model
P D T Spænding
Antal
poler
Lederens tværsnit
(mm2)
Kabelhylster
Kabellængde
(m)
Forbindelsestype
F=Fase
N=Neutral
T=Jord
Maks. effekt med:
oprullet kabel (kapacitet 1
kontakt 16 A ved 230 V)
udrullet kabel (belastning
3-faset fordeler)
280-230V-MF
280-230V-MF-P/S
●
- - Enfaset 230 V 2
1
H05 VV-F (pvc)
17+1
F-N
900 W
1400 W
H07 RN-F (gummi)
12+1
F-N
900 W
1400 W
1,5
H05 VV-F (pvc)
15+1
F-N
1100 W
2300 W
2,5
H05 VV-F (pvc)
10+1
F-F-N-N
1900 W
3500 W
H07 RN-F (gummi)
8+1
F-F-N-N
1900 W
3500 W
●
- - Enfaset 230 V 3
1
H05 VV-F (pvc)
14+1
F-N-T-T
900 W
1400 W
H07 RN-F (gummi)
10+1
F-N-T-T
900 W
1400 W
1,5
H05 VV-F (pvc)
14+1
F-N-T-T
1200 W
2300 W
H07 RN-F (gummi)
9+1
F-N-T-T
1200 W
2300 W
2,5
H05 VV-F (pvc)
9+1
F-F-N-N-T-T
1900 W
3500 W
H07 RN-F (gummi)
7+1
F-F-N-N-T-T
1900 W
3500 W
280-400V-TRF
●
- - Trefaset 400 V 4
1
H05 VV-F (pvc)
11+1
F-F-F-T-T
1100 W
2300 W
H07 RN-F (gummi)
10+1
F-F-F-T-T
1100 W
2300 W
1,5
H05 VV-F (pvc)
10+1
F-F-F-T-T
1400 W
4000 W
H07 RN-F (gummi)
8+1
F-F-F-T-T
1400 W
4000 W
2,5
H05 VV-F (pvc)
8+1
F-F-F-T-T
2000 W
6000 W
H07 RN-F (gummi)
5+1
F-F-F-T-T
2000 W
6000 W
●
- - Trefaset 400 V 5
1
H05 VV-F (pvc)
11+1
F-F-F-N-T-T
1000 W
2300 W
H07 RN-F (gummi)
10+1
F-F-F-N-T-T
1000 W
2300 W
1,5
H05 VV-F (pvc)
8+1
F-F-F-N-T-T
1400 W
4000 W
H07 RN-F (gummi)
7+1
F-F-F-N-T-T
1400 W
4000 W
280-MT
- - - -
-
6
pvc
15+1
T-T-T-T-T-T
Maks. strøm afhængigt af installeret tang:
50 A (Mod. 280-MT-50A)
10 A (Mod. 280-MT-ADFL)
16
pvc
10+1
T-T-T-T-T-T
Maks. strøm afhængigt af installeret tang:
100 A (Mod. 280-MT-100A)
290-230V
-
●
●
12 V ~
2
1
H05 VV-F (pvc)
15+1
F-N
Effekt 50 VA (maks. 4,5 A)
H07 RN-F (gummi)
14+1
F-N
-
●
●
24 V ~
2
1
H05 VV-F (pvc)
15+1
F-N
Effekt 50 VA (maks. 2,3 A)
H07 RN-F (gummi)
14+1
F-N
Driftstemperatur
fra -5 °C til + 40 °C (fra 23 °F til 104 °F)
Kapslingsklasse
IP44 for modeller uden beskyttelseshætte - IP45 for modeller med beskyttelseshætte
P=Thermische bescherming, D=Thermische ampèremeter onderbreker, T=Transformator
P=Termisk beskyttelse, D=Amperometrisk termosikring, T=Transformator
TECHNISCHE SPECIFICATIES
Содержание S. 280
Страница 2: ...2...