Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 66 of 74
Criteria
Specification
Power
Battery Pack
Lithium Thionyl Chloride Pack with protective circuitry
Voltage Range
3.0 to 3.7 V DC
Nominal Battery Life
20 years
Battery Access
Field replaceable
Battery Life Remaining Indicated
In months
Information Retention
Flash memory for permanent information retention without power
Testing Proof Verification
Compatibility
•
Most sonic nozzles provers that use IrDA
•
Pulse output
•
Black and White flag
Model 5 Compatibility
•
IrDA interface
•
Prover interface box
•
Black and White flag
•
Two (2) minute proving time
Flow Detection
White Flow Indicator
Uncorrected Prover Testing
White flow indicator on most provers
Communication
Optical Reading Port Requirements
•
Optical probe
•
Dresser MeterWare software
(data downloads, programming, firmware upgrades)
Pulse Type
Two (2) user-selectable Form A Outputs
Output Representation
•
Compensated
•
Non-compensated
•
Fault
•
Disabled
Pulse Rate
User scalable: x 1, x 10, x 100, or x 1000 cu. ft
Pulse Duration
User scalable: 50, 150, or 250 ms
AMR Type
Any Form A pulse collector
Dedicated Fault Output
Form B (500 ms pulse duration)
Isolated Outputs?
Yes
Maximum Input Voltage
8.2V
Flow Selection
Flow Direction
Forward, Reverse, Forward-Reverse, Reverse-Forward, Reverse
Alarms
Alarm Notifications
•
High/low temperature
•
High flow
•
Low battery