Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 8 of 74
The magnet can be purchased as part of the Communications Kit (refer to Figure 85) or individually by
part number, as shown in Table 1. Contact the Factory for pricing.
Table 1: Magnet Part Numbers
Part
Number (P/N)
Communications Kit
060542-000
Individual Magnet
060541-000
4.1.2
LCD Screen Displays
The home or default screen displays either Compensated Volume or Non-Compensated Volume,
depending on the meter version and customer configuration. After approximately thirty (30) seconds of
inactivity, the home screen displays.
Swipe the magnet vertically over
the black dot on the meter’s label until the screen you want
to view
displays. The screens always display in the order shown in Table 2. Depending on the meter configuration,
some screens might not display.
After the value’s name or parameter displays for
three to five (3
–
5) seconds, the screen displays the
parameter’s value.
Note:
Use the Dresser MeterWare software to configure parameters on the screens by
selecting or clearing the checkbox for the parameter to be displayed (refer to the
Dresser
MeterWare Software Manual
).
Table 2: Scrolling Sequence of LCD Screens
Displayed on Screen
Represents
Function
COMPENSATED VOLUME
Compensated Volume
Displays non-compensated volume that has been
corrected to standard conditions
NON-COMPENSATED
VOLUME
Non-Compensated Volume
Displays actual non-compensated volume
LINETEMP
Line Temperature
Displays live line temperature
FIXED P
Fixed Line Pressure
Displays the line pressure as entered by the user
FLOWRATE
Flow Rate
Displays uncorrected flow rate (average of latest
thirty (30) seconds of captured data)
MTR INFO
Meter Info
Displays meter size and type
LEAKTEST
Leak Test
Performs a functional test to determine low flow
leakage downstream of the meter
PROVE CV
Compensated Prove Mode
Allows for compensated volume accuracy testing
PROVE UV
Non-Compensated Prove Mode
Allows for non-compensated volume accuracy
testing
BATTVOLT
Battery Voltage
Displays battery voltage
REM LIFE
Remaining Battery Life
Calculates remaining battery life and displays it in
months
FIRM REV
Firmware Revision
Displays the current firmware revision
LCD TEST
LCD Test
Tests all display segments