Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 65 of 74
17
Specifications
Table 18: Meter Specifications
Criteria
Specification
Model number
10C25 Meter
Physical
Overall Dimensions
Side Inlet Orientation: 9.04
” (L) x
6.625
” (W) x
5.03
” (H)
Top Inlet Orientation:
9.04” (L) x
5.71
” (W) x 6.70” (H)
Carton Dimensions
11-1/16 x 9-1/8 x 13-1/8
Net Weight/Shipping Weight
9.5 lb/11 lb
Connections
30 LT/45 LT/#3, #4 Sprague,1-
1/2”FNPT
Maximum Allowable Operating
Pressure (MAOP)
25 psig
Operating Temperature Range
-40°F to 140°F (-40°C to 60°C)
Gas Application
Clean, non-corrosive dry gas
Display
Display Type
LCD with 10 mm digits
Capacity Registration
5, 6, 7, or 8 digits
Screens
20 (user selectable)
Screen Scrolling
Magnetic switch
Temperature Measurement System (Electronic Index)
Type
Extremely Stable Class A, PT 1000 RTD
Range
-40°F to 140°F (-40°C to 60°C)
Total Ambient Temperature Effect
Less than 0.1°F (0.05°C) over entire temperature range
Pressure Compensation
Programmable Fixed Factor
Computational Accuracy
Computation
+/- 0.25% of compensated volume reading
Data Logging
Data Logged
150 days of hourly logs
Logged Data
•
Time Stamp
•
Compensated Volume
•
Non-Compensated Volume
•
Line Temperature
•
Battery Voltage
•
Faults
•
Alarms
Audit Trail
•
Parameter
•
Time Stamp
•
Old Value
•
New Value
Data Exportable
Microsoft Excel