Meter Operation
This section provides information about using and configuring the meter.
11.1
MeterWare Software Information
The Dresser MeterWare software can be installed on your computer to configure the meter, download its
logged data, and update the meter’s firmware. An infrared cable using the IrDA protocol enables
the
MeterWare software to communicate with the meter (refer to Appendix A).
After the MeterWare software connects to the meter, a Live Data screen displays current operating
conditions. The Volume Configuration screen provides the ability to adjust volume information, such as
odometer readings and pulse output configurations. Faults and alarms are configurable,
and the meter’s
LCD screens are selectable.
For more information about the installation and operation of the MeterWare software, refer to the
Dresser MeterWare Software Manual
.
11.2
Volume Measurement
11.2.1
Imperial or Metric Measurement Options
Use the Dresser MeterWare software to configure the following parameters of the LCD screen:
•
Volumetric Units
•
Temperature (Fahrenheit or Celsius)
•
Fixed Pressure Factor (psi or kPa)
11.2.2
Volume Detection
Volume from the 10C25 meter is detected with a volume input board. This volume input board uses the
same Wiegand sensor technology used in other Dresser instruments.
There are five (5) volume accumulation methods, which are based on the capability to read either the
forward or the reverse flow directions, as shown in Table 6.
Table 6: Volume Accumulation Methods
Volume Accumulation
Measured Flow Source
Forward
Reverse
Calculated Flow
Forward minus (-) Reverse
✓
✓
Volume in Reverse flow is subtracted from the volume
calculated in Forward flow.
Reverse minus (-) Forward
✓
✓
Volume in Forward flow is subtracted from the volume
calculated in Reverse flow.
Reverse
X
✓
Volume in Reverse flow only is calculated. All flow in the
Forward direction is ignored.
Forward
✓
X
Volume in Forward flow only is calculated. All flow in the
Reverse direction is ignored.