Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 53 of 74
13.3
Testing Modes
The following sections explain the testing modes for the meter. The meter can test both the compensated
and non-compensated accuracy with the IrDA prover cable.
13.3.1
Testing Compensated Accuracy
To test the compensated accuracy of the meter, perform the following steps:
1.
Select the following settings:
•
TC
•
% PROOF, % ERROR or % ACCY (depending on company standards)
•
INTEST or OUTTEST (depending on how the company tests)
•
ENGLISH
•
Either 2-RATE or 3-RATE
•
OPTIC
•
INDEX 1
2.
Fill in the required screens on the left side of the prover display screen to enable the
PRESS CLAMP
BUTTONS
button.
3.
Click
PRESS CLAMP BUTTONS
to start the test. Press both clamp buttons at the same time to lower
the arms to the meter.
4.
Place the meter into the Compensated Prove mode (refer to Section 13.1.1).
After the meter is in prove mode, the red light changes from flashing to solid.
The meter test is ready to start.
5.
After the meter tests complete, press
ACCEPT
to save the meter test results.
13.3.2
Testing Non-Compensated Accuracy
To test the non-compensated accuracy of the meter, perform the following steps:
1.
Select the following settings:
•
REG
•
% PROOF, % ERROR or % ACCY (depending on company standards)
•
INTEST or OUTTEST (depending on how the company tests)
•
ENGLISH
•
Either 2-RATE or 3-RATE
•
OPTIC
•
INDEX 1
2.
Fill in the required screens on the left side of the prover display screen to enable the
PRESS CLAMP
BUTTONS
button.