Page 54 of 74
3.
Click
PRESS CLAMP BUTTONS
to start the test. Press both clamp buttons at the same time to lower
the arms to the meter.
4.
Place the meter into the Non-Compensated Prove mode (refer to Section 13.1.2).
After the meter is in prove mode, the red light changes from flashing to solid.
The meter test is ready to start.
5.
After the meter tests complete, press
ACCEPT
to save the meter test results.
13.4
Proving with Dresser Model 5 Transfer Prover
To use the Dresser Model 5 Transfer Prover, connect the IrDA cable to establish a connection with the
meter, and then configure the Model 5 Prover software.
Table 14: Prover Parts Table
Part Description
Part Number
Prover Cable
060673-000
Prover Interface Holder
060658-000
Magnet
(or part of Communications Kit)
060541-000
13.4.1
Establish IrDA Prover Cable Connection
1.
Insert the IR prover cable holder in the open slot under the meter label.
The cable holder aligns the cable with the meter’s IR window and helps hold it in place.
2.
Insert the IR prover cable in the cable holder.
Figure 70: Location for holder installation
Figure 71: IR prover holder in slot
IR window
IR cable slot