Dresser Model 10C25 Series K Installation, Operation, and Maintenance Manual
© 2018 Natural Gas Solutions North America, LLC
Page 4 of 74
1
Introduction
This manual provides information for installing, testing, operating, and maintaining the Dresser 10C25
Series K Digital Index non-compensated meter (10C25 DI) and the 10C25 Temperature Compensated
Digital Index meter (10C25 DI-T). Please read the entire manual for information about how to properly
and safely install, use, and maintain the meter and some of its accessories.
This manual provides recommendations when no established company procedure or practice is available.
The following additional resources are available:
•
The
Dresser MeterWare Software Manual
, which contains detailed
information about the meter’s
digital index software
•
An Installation Supplement guide, which ships with the meter
Manuals are available by request or online at
2
Overview
The Dresser 10C25 Series K (DI/DI-T) meter continues the Dresser legacy of superior long-term rotary
meter performance in a compact oil-free design.
The 10C25 meter body offers:
•
A maximum flow rate of 1,000 acfh.
•
An MAOP (maximum allowable operating pressure) of 25 psig.
•
A functional and aesthetic design for situations in which a larger meter may draw unwanted
attention.
•
Bi-directional flow capability that allows for more compact meter set designs.
•
Direct replacement for the Dresser Series Z 5C15 and 8C15 ROOTS meters.
The 10C25 digital indexes offer:
•
Innovative interconnection for AMR (automatic meter reading) devices pulse outputs including ease
of mounting and IP-68 watertight connections.
•
A fast, two (2)-minute proving capability on Dresser Model 5 Transfer Provers and on common sonic
nozzle bench provers.
•
Two (2) programmable pulse output signals.
•
Dedicated alarm output.
•
150 days of hourly logs stored in non-volatile memory.
•
Programmable fixed-factor pressure correction.
The Dresser MeterWare software provides the user interface to the 10C25 digital indexes with an IrDA
(infrared) communication interface and is compatible with multiple Dresser metering products.